Danby DDR020BIWDB Dehumidifier Manual

The Danby DDR020BIWDB is a 20-pint capacity dehumidifier designed for residential use. It features a compact design, electronic controls, auto-restart, continuous drain option, washable filter, adjustable humidity control, full tank alert with auto shut-off, and caster wheels for mobility. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation 7. Maintenance 8. Care & Cleaning 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Electronic control panel, 20-pint water tank, washable air filter, continuous drain hose connection, caster wheels, and carrying handle.

FeatureDescription
Capacity20 pints per day (at 60°F, 60% RH)
Control PanelElectronic with LED display and touch buttons
Humidity ControlAdjustable from 35% to 85% relative humidity
Auto RestartResumes previous settings after power interruption
Full Tank AlertLED indicator and auto shut-off when tank is full
Continuous DrainOption for hose connection (hose not included)
FilterWashable air filter for easy maintenance
MobilityFour caster wheels and carrying handle
Timer24-hour on/off timer function
Power CordStandard 115V, 60Hz plug

Installation

Unpack and inspect contents. Place on level surface.

  1. Remove packaging: Take unit out of box, remove all tape and protective materials.
  2. Position unit: Place on firm, level floor at least 12 inches from walls and furniture.
  3. Install filter: Ensure washable filter is properly seated in front grille.
  4. Check drain hose: For continuous drainage, attach hose to drain outlet at back.
  5. Plug into power outlet: Use dedicated 115V AC outlet.

WARNING! Do not operate in temperatures below 41°F (5°C). Ensure proper ventilation around unit.

First-Time Setup

Plug in unit; follow initial setup steps.

  1. Power on: Press POWER button on control panel.
  2. Set humidity level: Use UP/DOWN buttons to select desired humidity (35%-85%).
  3. Select fan speed: Choose LOW or HIGH fan setting.
  4. Set timer (optional): Use TIMER button to program on/off times.
  5. Check operation: Unit should begin dehumidifying; compressor may take 3 minutes to start.

CAUTION! Allow unit to sit upright for 24 hours if transported on its side.

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, FILTER RESET.

Display Indicators: Current humidity, Set humidity, Fan speed, Timer, Full tank, Filter clean.

Humidity Control: Adjust between 35% and 85% RH. Fan Speed: LOW for quiet operation, HIGH for maximum moisture removal. Timer: 24-hour programmable on/off timer. Filter Reset: Press after cleaning filter to reset reminder light. Continuous Mode: Runs continuously regardless of humidity level when set to lowest setting.

Operation

Normal operation for moisture removal.

  1. Power on: Press POWER button.
  2. Set desired humidity: Use UP/DOWN buttons to select target humidity.
  3. Select fan speed: Press FAN button to toggle between LOW and HIGH.
  4. Monitor: Display shows current room humidity.
  5. Water removal: Unit collects water in tank or drains continuously.
  6. Full tank: Unit shuts off automatically when tank is full; FULL indicator lights.
  7. Empty tank: Remove tank, empty water, replace securely.

Tip: For best efficiency, keep doors and windows closed in area being dehumidified.

Maintenance

Regular maintenance ensures optimal performance.

  1. Clean filter: Remove and wash filter every 2 weeks or as needed.
  2. Reset filter light: After cleaning, press and hold FILTER button for 3 seconds.
  3. Clean water tank: Empty and clean tank monthly with mild detergent.
  4. Check drain hose: Ensure continuous drain hose is clear if used.
  5. Clean exterior: Wipe cabinet with damp cloth.
  6. Off-season storage: Empty tank, clean unit, coil and store in dry place.

WARNING! Always unplug unit before performing any maintenance.

Care & Cleaning

Unplug before cleaning. Use soft cloth and mild detergent. Do not use abrasive cleaners.

CAUTION! Never immerse unit in water. Do not use chemicals on evaporator coils.

Regulatory Information

UL Listed. FCC Part 15: Class B digital device; complies with interference limits for residential use. This product contains refrigerant; dispose of according to local regulations. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingNo powerCheck power cord connection; ensure outlet works; check circuit breaker.
Little moisture removalRoom too coldOperate only above 41°F (5°C); check filter cleanliness.
Water leakingTank not seatedEnsure tank is properly inserted; check for cracks in tank.
Loud noiseUneven surfacePlace on level floor; check for loose parts.
Full tank light on (empty tank)Float stuckRemove tank, check float mechanism moves freely.
Filter light onDirty filterClean filter; press and hold FILTER button to reset.
Ice on coilsLow temperatureTurn unit off; allow ice to melt; restart in warmer conditions.

Reset: Unplug for 5 minutes to reset electronic controls.

Service: 1-800-263-2629; www.danby.com

Danby DDR020BIWDB Dehumidifier Manual © - All Rights Reserved 2025