Danby DDR020BJ2WDB Dehumidifier Manual

The Danby DDR020BJ2WDB is a 20-pint capacity dehumidifier designed for residential use in areas up to 500 sq. ft. It features an automatic shut-off, continuous drainage option, digital humidity display, 24-hour timer, washable air filter, and low-temperature operation capability. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drainage 7. Operating Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, Removable water bucket, Washable air filter, Continuous drain hose port, Casters for mobility, Handle for transport.

FeatureDescription
Capacity20 pints per day (at 60°F, 60% RH)
Digital DisplayShows current humidity level and settings
Automatic Shut-OffTurns off when bucket is full or removed
Continuous DrainageOption for hose connection (not included)
24-Hour TimerProgram on/off cycles
Low-Temperature OperationAuto-defrost function for cooler environments
Washable FilterRemovable and reusable air filter
Bucket Full IndicatorLED light alerts when bucket needs emptying
HumidistatAdjustable from 35% to 85% relative humidity
Power Cord6-foot length with storage wrap

Installation

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place unit at least 12 inches from walls and furniture for proper airflow.
  2. Bucket Installation: Ensure water bucket is securely inserted until it clicks.
  3. Power Connection: Plug into a dedicated 120V AC outlet. Do not use extension cords.
  4. Initial Check: Ensure air filter is clean and properly seated.

WARNING! Do not operate in standing water. Ensure unit is upright before plugging in.

First-Time Setup

Power on dehumidifier; follow initial setup steps.

  1. Set Humidity Level: Press HUMIDITY button to set desired RH (recommended 45-50%).
  2. Select Fan Speed: Choose HIGH or LOW fan setting based on room size and moisture level.
  3. Timer Setup: Use TIMER button to program automatic start/stop times if desired.
  4. Continuous Drain: Connect 5/8" ID hose to drain port if using continuous drainage option.

CAUTION! Allow unit to stand upright for 24 hours if transported on its side.

Specifications

Controls and Settings

Access controls via digital panel on top of unit.

Control Panel: POWER, HUMIDITY (+/-), FAN SPEED (HIGH/LOW), TIMER, MODE (CONTINUOUS/AUTO).

Humidity Control: Adjust set point from 35% to 85% RH. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: Program 1-24 hours for automatic operation. Mode: CONTINUOUS runs constantly, AUTO cycles based on humidity setting. Filter Reset: Press and hold FILTER button for 3 seconds after cleaning filter.

Connecting Drainage

Continuous drainage option for unattended operation.

  1. Turn off and unplug unit.
  2. Remove water bucket from front of unit.
  3. Connect standard 5/8" ID garden hose to drain port (hose not included).
  4. Route hose to floor drain, sink, or outdoors with downward slope.
  5. Replace bucket (unit will not operate without bucket properly installed).
  6. Select CONTINUOUS mode on control panel.

Tip: Ensure hose has no kinks or upward loops to prevent water backup.

Operating Modes

Multiple operating modes for different needs.

  1. Auto Mode: Unit cycles on/off to maintain set humidity level.
  2. Continuous Mode: Runs constantly until turned off or bucket is full.
  3. Turbo Mode: HIGH fan speed for maximum moisture removal.
  4. Sleep Mode: LOW fan speed and dimmed display for nighttime operation.
  5. Laundry Mode: Concentrated drying for laundry rooms (runs 4 hours continuously).

WARNING! Do not operate in temperatures below 41°F (5°C) without auto-defrost feature enabled.

Maintenance

Regular maintenance ensures optimal performance.

Care & Cleaning

Unplug before cleaning. Clean water bucket with mild detergent; rinse thoroughly.

CAUTION! Do not immerse unit in water. Never use gasoline, thinners, or abrasive cleaners.

Regulatory Information

UL Listed. Meets EPA energy efficiency standards. This product contains refrigerant R410A. For proper disposal, consult local regulations. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onPower issue/bucketCheck outlet; ensure bucket is properly inserted; reset GFCI outlet.
Not removing moistureFilter/temperatureClean air filter; ensure room temperature above 41°F; check humidity setting.
Bucket full light on (empty bucket)Float switchCheck for obstruction in bucket; ensure float moves freely.
Water leakingHose connection/bucketEnsure hose connections are tight; check bucket for cracks; ensure unit is level.
Loud noiseFan/compressorCheck for foreign objects in fan; ensure unit is on level surface.
Ice on coilsLow temperatureTurn unit off and allow ice to melt; move to warmer location.

Reset: Unplug for 5 minutes, then restart.

Service: 1-800-263-2629; www.danby.com