Danby DDR020BJWDB Dehumidifier Manual

The Danby DDR020BJWDB is a 20-pint capacity dehumidifier designed for residential use in spaces up to 500 sq. ft. It features an automatic shut-off, continuous drainage option, digital humidity readout, 24-hour timer, washable filter, and energy-efficient operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Instructions 7. Maintenance & Cleaning 8. Storage Instructions 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Digital control panel, Water tank with full indicator, Continuous drain hose port, Washable air filter, Casters for mobility.

FeatureDescription
CapacityRemoves up to 20 pints of moisture per day (at 80°F, 60% RH)
Digital ControlsElectronic touchpad with humidity display and settings
Automatic Shut-OffTurns off when tank is full; indicator light illuminates
Continuous DrainageOption to connect hose for automatic water removal
24-Hour TimerProgram start/stop times for energy savings
Washable FilterRemovable and reusable air filter
Humidity ControlAdjustable from 35% to 85% relative humidity
MobilityFour swivel casters for easy room-to-room movement
Auto RestartResumes previous settings after power interruption
Power Cord StorageBuilt-in compartment for cord management

Installation

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place unit at least 6-12 inches from walls and furniture for proper airflow.
  2. Check filter: Ensure washable filter is properly installed before operation.
  3. Continuous drainage (optional): Attach 5/8" ID hose to drain port and route to floor drain.
  4. Plug into dedicated 115V AC power outlet.

WARNING! Do not use extension cords. Ensure unit is upright for at least 24 hours if transported on its side.

First-Time Setup

Plug in unit; control panel will illuminate.

  1. Set humidity level: Press HUMIDITY button to select desired level (40-50% recommended).
  2. Select fan speed: Choose HIGH or LOW setting for dehumidification speed.
  3. Set timer (optional): Use TIMER button to program operation schedule.
  4. For continuous drainage: Ensure hose is securely connected and water can flow freely.

CAUTION! Operate only within 41°F to 95°F temperature range. Do not block air intake or exhaust.

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY SET, FAN SPEED (HIGH/LOW), TIMER, FILTER RESET.

Display Indicators: Current humidity, Set humidity, Tank full, Filter clean, Timer active.

Humidity Control: Adjust between 35-85% RH in 5% increments. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: Program 1-24 hours for automatic start/stop. Filter Alert: FILTER light illuminates when cleaning is required (approximately every 250 hours).

Operating Instructions

For normal operation with water tank.

  1. Press POWER to turn unit on.
  2. Set desired humidity level using HUMIDITY buttons.
  3. Select fan speed (HIGH or LOW).
  4. Unit runs until set humidity is reached or tank is full.
  5. When TANK FULL light illuminates, power off, remove tank, empty, and replace.
  6. Unit automatically resumes operation when tank is replaced.

Tip: For maximum efficiency, keep doors and windows closed during operation.

Maintenance & Cleaning

Unplug unit before any maintenance.

  1. Clean air filter: Remove every 2 weeks, wash with warm water and mild detergent, dry completely before reinstalling.
  2. Reset filter indicator: Press and hold FILTER button for 3 seconds after cleaning.
  3. Clean water tank: Empty and wash monthly with mild detergent; rinse thoroughly.
  4. Clean exterior: Wipe with soft, damp cloth; do not use abrasive cleaners.
  5. Check drain hose: Ensure continuous drain hose is clear of obstructions.

WARNING! Never operate without filter. Do not immerse unit in water.

Storage Instructions

When not in use for extended periods:

  1. Unplug unit and empty water tank completely.
  2. Clean filter and tank as described above.
  3. Wrap power cord and store in compartment.
  4. Store upright in cool, dry location.
  5. Cover unit to prevent dust accumulation.

CAUTION! Allow unit to dry completely before storage to prevent mold/mildew.

Regulatory Information

UL Listed. FCC Part 15: Class B digital device; complies with interference limits for residential use. This product contains refrigerant R-410A. For proper disposal, contact local waste management authorities. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not startNo power/tank fullCheck power outlet; ensure tank is empty and properly seated.
Low moisture removalRoom temperature/filterEnsure room temp is 41-95°F; clean air filter; check for air blockage.
Water leakageTank/drain hoseEnsure tank is properly positioned; check drain hose connection.
Loud noise/vibrationUneven surfacePlace on level floor; check for loose parts.
Frost on coilsLow temperatureTurn unit off; allow frost to melt; restart when room temp >65°F.
Filter light onDirty filterClean filter as instructed; reset filter indicator.

Reset: Unplug for 5 minutes, then restart.

Service: 1-800-263-2629; www.danby.com

Danby DDR020BJWDB Dehumidifier Manual © - All Rights Reserved 2025