The Danby DDR050BCWDB-ME-6 is a 50-pint capacity dehumidifier designed for medium to large rooms. It features an electronic control panel with digital display, 24-hour timer, continuous drain option, auto-defrost function, washable air filter, and adjustable humidity settings. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Electronic control panel, Digital humidity display, Water tank with full indicator, Continuous drain port, Washable air filter, Casters for mobility.
| Feature | Description |
|---|---|
| Capacity | 50 pints per day (at 60°F, 60% RH) |
| Control Panel | Electronic with LED display and touch buttons |
| Humidity Control | Adjustable from 35% to 85% relative humidity |
| Timer | 24-hour programmable on/off timer |
| Auto Defrost | Automatically defrosts coils in low temperatures |
| Continuous Drain | Garden hose connection for continuous operation |
| Water Tank | Removable bucket with full indicator and auto shut-off |
| Air Filter | Washable mesh filter for dust and particles |
| Mobility | Four casters for easy movement |
| Power Cord | 6-foot cord with storage wrap |
Unpack and inspect contents. Place on level surface.
WARNING! Do not place near heat sources or in direct sunlight. Ensure proper clearance for airflow.
Plug in unit; follow initial setup steps.
CAUTION! Allow unit to stand upright for 24 hours if transported on its side.
Control Panel: POWER, MODE, HUMIDITY, TIMER, FAN SPEED (LOW/HIGH).
Display: Shows current humidity, set point, timer status, filter alert, and tank full indicator.
Modes: CONTINUOUS (runs constantly), AUTO (maintains set humidity), DRY (for laundry rooms). Fan Speed: LOW for quiet operation, HIGH for maximum moisture removal. Timer: Set 1-24 hours for automatic start/stop. Humidity Setting: Adjust in 5% increments from 35% to 85%.
Two drainage options: Water tank or continuous drain.
Tip: For basement use, continuous drain is recommended to prevent overflow.
Supports multiple operating modes for different needs.
WARNING! Do not operate below 41°F without auto-defrost function enabled.
Regular maintenance ensures optimal performance.
Unplug before cleaning. Use only mild soap and water; never immerse in water.
CAUTION! Do not use gasoline, thinners, or abrasive cleaners. Keep coils and vents clean for efficiency.
UL Listed; meets U.S. safety standards. Energy Star certified for energy efficiency. Refrigerant EPA compliant. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | Power/water tank | Check power connection; ensure tank is properly seated. |
| Low moisture removal | Filter/temperature | Clean air filter; ensure room temp above 41°F. |
| Water leakage | Drain hose/tank | Check hose connections; ensure tank is not cracked. |
| Loud noise | Uneven surface/fan | Place on level surface; check for obstructions in fan. |
| Display not working | Power surge | Unplug for 5 minutes, then restart. |
| Ice on coils | Low temperature | Auto-defrost should activate; move to warmer area. |
Reset: Unplug for 10 minutes to reset electronic controls.
Service: 1-800-263-2629; www.danby.com