Danby DDR050BJ2WDB Dehumidifier Manual

The Danby DDR050BJ2WDB is a 50-pint dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage option, 24-hour timer, washable air filter, auto-restart after power interruption, and low-temperature operation capability. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drainage 7. Operating Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Control panel with digital display, Water tank with full indicator, Continuous drain port, Washable air filter, Casters for mobility, Handle for transport.

FeatureDescription
Humidity ControlAutomatic humidity sensing and adjustment
Water Tank Capacity50-pint removable bucket with full alert
Continuous DrainageGarden hose connection for automatic water removal
24-Hour TimerProgrammable on/off scheduling
Auto RestartResumes previous settings after power outage
Low Temp OperationFunctions effectively in cooler environments
Air FilterWashable filter for improved air quality
Digital ControlsLED display with touch button interface
MobilityFour casters and carrying handle
Power CordStandard 120V grounded plug

Installation

Unpack and inspect contents. Place on level surface.

  1. Positioning: Place unit on flat, stable surface away from walls and furniture (minimum 12 inches clearance).
  2. Check filter: Ensure air filter is properly installed before operation.
  3. Power connection: Plug into dedicated 120V outlet; avoid extension cords.
  4. Drainage setup: For continuous drainage, attach hose to drain port and route to floor drain.

WARNING! Do not operate in standing water. Ensure proper ventilation around unit.

First-Time Setup

Plug in unit; follow initial setup procedure.

  1. Select location: Choose area with high humidity, away from heat sources.
  2. Set humidity level: Press HUMIDITY button to select desired RH% (40-60% recommended).
  3. Choose mode: Select CONTINUOUS or AUTO mode based on needs.
  4. Timer programming: Set 24-hour timer if needed using TIMER button.
  5. Test operation: Allow unit to run for 15 minutes to verify proper function.

CAUTION! Do not block air intake or exhaust. Keep children away from unit.

Specifications

Controls and Settings

Control Panel: POWER, MODE, HUMIDITY, FAN SPEED, TIMER, FILTER RESET.

Display Indicators: Current humidity, Set humidity, Timer status, Filter alert, Full tank alert, Defrost indicator.

Modes: CONTINUOUS (runs constantly), AUTO (maintains set humidity), DRY (for laundry rooms). Fan Speeds: HIGH, LOW, QUIET. Humidity Settings: 35% to 85% in 5% increments. Timer: 1-24 hours programmable. Filter Reset: Resets filter maintenance reminder after cleaning.

Connecting Drainage

Continuous drainage option for unattended operation.

  1. Turn off and unplug unit.
  2. Remove drain plug from back of unit.
  3. Attach standard garden hose (¾" diameter) to drain port.
  4. Route hose to floor drain, sink, or outside.
  5. Ensure hose has downward slope without kinks.
  6. Replace water bucket if using tank collection method.

Tip: Check hose connection periodically for leaks. Empty bucket immediately when full indicator lights.

Operating Modes

Multiple operation modes for different needs.

  1. AUTO Mode: Unit cycles on/off to maintain set humidity level.
  2. CONTINUOUS Mode: Runs continuously regardless of humidity.
  3. DRY Mode: Optimized for laundry room drying.
  4. Timer Operation: Program unit to turn on/off at specific times.
  5. Fan Only: Circulates air without dehumidifying.
  6. Defrost Cycle: Automatically activates in low temperatures to prevent coil freezing.

WARNING! Do not operate below 41°F (5°C) for extended periods. Allow defrost cycle to complete automatically.

Maintenance

Regular maintenance ensures optimal performance.

  1. Daily: Check and empty water tank when full.
  2. Weekly: Clean air filter under running water; dry completely before reinstalling.
  3. Monthly: Clean exterior with soft, damp cloth.
  4. Seasonally: Clean condenser coils with soft brush.
  5. Annually: Check drain hose for obstructions.

Filter Reset: After cleaning filter, press and hold FILTER button for 3 seconds to reset reminder.

Care & Cleaning

Unplug before cleaning. Use mild detergent and soft cloth only.

  1. Exterior: Wipe with damp cloth; do not use abrasive cleaners.
  2. Water Tank: Wash with mild soap and water; rinse thoroughly.
  3. Air Filter: Remove and wash under lukewarm water; air dry completely.
  4. Condenser Coils: Gently brush away dust and debris.
  5. Grilles: Vacuum with brush attachment to remove dust.

CAUTION! Never immerse unit in water. Do not use chemical cleaners on internal components.

Regulatory Information

UL Listed: Meets UL standard 474. Energy Star: Certified for energy efficiency. FCC Part 15: Class B digital device compliant. EPA Refrigerant: Uses R410A, an environmentally friendly refrigerant. For support, visit www.danby.com or contact 1-800-263-2629. Manufactured for Danby Products Inc., Findlay, OH 45840.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/full tankCheck power connection; ensure tank is empty and properly seated.
Low dehumidificationDirty filter/extreme tempsClean air filter; ensure room temperature above 41°F.
Water leakageImproper hose connectionCheck drain hose for kinks; ensure proper connection to drain port.
Loud operationUneven surface/obstructionPlace on level surface; check for objects touching unit.
Ice on coilsLow temperature operationAllow defrost cycle to complete; move to warmer area if below 41°F.
Error codes on displaySensor/system issuesUnplug for 10 minutes, then restart; consult service if persistent.

Reset: Unplug for 10 minutes to reset control system.

Service: 1-800-263-2629; www.danby.com

Danby DDR050BJ2WDB Dehumidifier Manual © - All Rights Reserved 2025