Danby DDR050BJP2WDB Dehumidifier Manual

The Danby DDR050BJP2WDB is a 50-pint dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage option, auto-restart, washable air filter, and digital controls with LED display. It operates on 115V/60Hz power and is suitable for areas up to 3000 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, 50-pint capacity water tank, washable filter, continuous drain hose connection, casters for mobility, and auto-defrost function.

FeatureDescription
Digital Control PanelLED display with touch controls for humidity setting and timer
50-Pint CapacityRemoves up to 50 pints of moisture per day (at 80°F, 60% RH)
Continuous DrainageOption to connect hose for automatic water removal
Washable Air FilterCaptures airborne particles; can be cleaned and reused
Auto-RestartResumes previous settings after power interruption
Auto-DefrostPrevents coil freezing in low temperatures
Full Tank AlertLED indicator and auto-shutoff when tank is full
24-Hour TimerProgrammable on/off cycles
CastersFour wheels for easy mobility
Power Cord StorageBuilt-in compartment for cord management

Installation & Placement

Unpack and inspect contents. Ensure all parts are present and undamaged.

  1. Choose location: Place on level floor in center of room, away from walls/furniture (min 12 inches clearance).
  2. Check airflow: Ensure air intake and outlet are unobstructed.
  3. Connect drainage (optional): Attach hose to drain port for continuous operation.
  4. Plug into grounded 115V outlet.

WARNING! Do not use extension cords. Ensure proper ventilation around unit.

First-Time Setup

Power on dehumidifier; follow initial setup steps.

  1. Set humidity level: Press HUMIDITY button to select desired RH (30%-80%).
  2. Select fan speed: Choose LOW or HIGH with FAN button.
  3. Set timer (optional): Use TIMER button to program auto on/off.
  4. Check filter: Ensure filter is clean and properly installed.
  5. Place empty water tank: Slide tank into base until it clicks.

CAUTION! Handle water tank carefully to avoid spills.

Specifications

Controls and Settings

Access controls via digital panel on top of unit.

Control Panel: POWER, HUMIDITY (+/-), FAN (LOW/HIGH), TIMER (1-24 hours), FILTER ALERT reset.

Humidity Control: Set between 30%-80% RH in 5% increments. Fan Speed: LOW for quiet operation, HIGH for maximum moisture removal. Timer: Set delay start (1-24 hours) or auto shutoff. Filter Alert: LED lights when filter needs cleaning. Full Tank Indicator: Red LED lights when tank requires emptying.

Operation Modes

Normal Mode: Runs continuously until set humidity is reached. Continuous Mode: Runs non-stop (bypasses humidity setting). Auto-Defrost Mode: Activates automatically when coil temperature drops below 41°F.

  1. Press POWER to turn on.
  2. Set desired humidity with HUMIDITY buttons.
  3. Select fan speed with FAN button.
  4. For continuous operation, set humidity to "CO" (Continuous).
  5. Unit will cycle on/off to maintain set humidity level.

Tip: Close windows and doors for optimal performance.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean air filter every 2 weeks: Remove, wash with mild detergent, dry completely, reinstall.
  2. Empty water tank: When FULL indicator lights, pull tank straight out, empty, and replace.
  3. Clean exterior: Wipe with damp cloth; do not use abrasive cleaners.
  4. Clean water tank: Monthly, wash with mild soap, rinse thoroughly.
  5. End-of-season storage: Clean unit, empty tank, coil dry mode for 24 hours, store upright.

WARNING! Unplug unit before any maintenance. Do not immerse in water.

Drainage Options

Two drainage methods: Manual (bucket) or Continuous (hose).

Manual: Use included 2-gallon tank; empty when full indicator lights.

Continuous:

  1. Turn off and unplug unit.
  2. Remove drain cap from back.
  3. Attach 5/8" ID hose (not included).
  4. Route hose to floor drain or suitable outlet.
  5. Ensure hose has downward slope without kinks.

CAUTION! Do not lift unit while hose is attached. Ensure proper drainage to prevent overflow.

Care & Storage

When not in use for extended periods:

  1. Run unit in "DRY" mode for 24 hours to dry internal components.
  2. Clean filter and water tank thoroughly.
  3. Empty any remaining water from tank and hoses.
  4. Coil power cord and store in compartment.
  5. Store upright in cool, dry place.

CAUTION! Do not store with water in tank. Protect from dust and moisture.

Regulatory Information

UL Listed: Meets safety standards UL 474. Energy Star: Certified for energy efficiency. EPA Refrigerant: Compliant with Section 608 of Clean Air Act. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/full tankCheck power outlet; ensure tank is empty and properly seated.
Poor dehumidificationDirty filter/closed doorsClean filter; ensure room is sealed; check temperature (above 41°F).
Water leakageMisaligned tank/hoseEnsure tank is fully inserted; check hose connections for leaks.
Loud noiseUneven surface/obstructionPlace on level floor; check for objects near fan.
Frost on coilsLow temperatureAuto-defrost should activate; move to warmer area if persistent.
Filter light onDirty filterClean filter; press and hold FILTER button for 3 seconds to reset.

Reset: Unplug for 5 minutes, then restart.

Service: 1-800-263-2629; www.danby.com

Danby DDR050BJP2WDB Dehumidifier Manual © - All Rights Reserved 2025