The Danby DDR050BJPWDB-6 is a 50-pint dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage capability, a 24-hour timer, washable air filter, auto-restart function, and low-temperature operation. Ideal for medium to large rooms up to 3000 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Control panel with digital display, Water tank with full indicator, Continuous drain hose connection, Washable air filter, Casters for mobility, Carrying handle.
| Feature | Description |
|---|---|
| Humidity Control | Automatic humidity sensing and adjustment (30%-90% RH) |
| Water Tank Capacity | Removable 50-pint capacity tank with full alert and auto shut-off |
| Continuous Drainage | Garden hose connection for continuous operation |
| 24-Hour Timer | Programmable on/off timer for energy efficiency |
| Auto Restart | Resumes previous settings after power interruption |
| Low Temperature Operation | Operates effectively down to 41°F (5°C) |
| Filter Indicator | Reminder to clean the washable air filter |
| Turbo Mode | Maximum moisture removal for high humidity conditions |
| Sleep Mode | Quiet operation with dimmed display for nighttime use |
| Mobility Features | Four casters and carrying handle for easy relocation |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not operate in standing water. Ensure proper ventilation around the unit.
Plug into grounded 115V outlet; follow initial setup procedure.
CAUTION! Do not use extension cords. Ensure hands are dry when operating controls.
Control Panel: POWER, MODE, TIMER, UP/DOWN buttons, FILTER indicator, TANK FULL indicator.
Display Indicators: Current humidity, Set humidity, Timer status, Filter alert, Tank full, Mode icons.
Humidity Setting: Adjust between 30% and 90% RH in 5% increments. Modes: Normal (standard operation), Turbo (maximum dehumidification), Sleep (quiet operation with dimmed display). Timer: Programmable 1-24 hours for automatic on/off. Filter Reset: Hold FILTER button for 3 seconds after cleaning filter.
Normal Mode: Standard dehumidification with balanced energy use. Turbo Mode: Maximum moisture removal for high humidity. Sleep Mode: Reduced noise and dimmed display for nighttime.
Tip: For energy savings, set humidity to 50% when occupied, 60% when unoccupied.
Two drainage methods: Manual (water tank) or Continuous (garden hose).
WARNING! Do not drink collected water. Empty tank regularly to prevent overflow.
Unplug unit before any maintenance. Monthly cleaning recommended.
CAUTION! Never immerse unit in water. Do not use chemical cleaners on filter.
For seasonal storage or extended non-use:
Important: Store at temperatures between 41°F and 95°F. Do not store with water in tank.
UL Listed: Meets UL standard 474. Energy Star: Certified for energy efficiency. FCC Part 15: Class B digital device compliant. Refrigerant: Contains R410a. For recycling information, contact local waste management. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | Power issue/tank full | Check power connection; ensure tank is properly seated; reset circuit breaker. |
| Poor dehumidification | Filter dirty/doors open | Clean air filter; close windows and doors; check room temperature. |
| Water leakage | Tank not seated/hose leak | Ensure tank clicks into place; check hose connections; level the unit. |
| Loud operation | Uneven surface/fan issue | Place on level surface; check for obstructions; contact service if noise continues. |
| Display not working | Power/control issue | Unplug for 5 minutes, then restart; check power source. |
| Ice on coils | Low temperature | Normal below 65°F; unit will auto-defrost; move to warmer area if persistent. |
Reset: Unplug for 5 minutes to reset electronic controls.
Service: 1-800-263-2629; www.danby.com