Danby DDR050BJPWDB-ME-6 Dehumidifier Manual

The Danby DDR050BJPWDB-ME-6 is a 50-pint dehumidifier designed for medium to large rooms, featuring electronic controls, a continuous drain option, auto-restart, turbo mode, a 24-hour timer, washable air filter, and auto-defrost function. It operates on 115V/60Hz power. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Storage Instructions 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Electronic control panel, removable water bucket with full-bucket alert and handle, continuous drain hose connection, washable air filter, casters for mobility, and auto-defrost.

FeatureDescription
Dehumidification Capacity50 pints per day (at 80°F, 60% RH)
Electronic ControlsDigital display with touchpad operation
Continuous Drain OptionGarden hose connection for unattended operation
Auto-RestartResumes previous settings after a power interruption
Turbo ModeIncreases fan speed for faster dehumidification
24-Hour TimerProgram on/off cycles
Washable Air FilterCaptures airborne particles; clean every 2 weeks
Auto-DefrostPrevents coil freezing in low temperatures
Full-Bucket AlertLight and audible signal when bucket is full
CastersFour wheels for easy room-to-room movement

Installation & Placement

Unpack and inspect contents. Place on a level, stable floor.

  1. Clearance: Ensure at least 12 inches of clearance on all sides, especially air intake and exhaust.
  2. Level Surface: Place on a flat surface to ensure proper operation and bucket seating.
  3. Power Outlet: Plug directly into a grounded 115V/60Hz outlet. Do not use an extension cord.
  4. Drain Option: For continuous drainage, attach a standard garden hose (not included) to the drain port and route to a floor drain or suitable container.

WARNING! Do not place near heat sources or in direct sunlight. Ensure the room temperature is between 41°F (5°C) and 95°F (35°C) for optimal operation.

First-Time Setup

Plug in the unit. The control panel will illuminate.

  1. Bucket Installation: Ensure the water bucket is correctly seated and pushed in fully until it clicks.
  2. Initial Settings: Press the POWER button. Use the UP/DOWN buttons to set your desired humidity level (40%-80% RH is recommended).
  3. Mode Selection: Select a mode (Continuous, Turbo, or Normal) based on your needs.
  4. Timer (Optional): Set the 24-hour timer via the TIMER button if desired.

CAUTION! Handle the unit with care during setup. Do not tilt or invert with water in the bucket.

Specifications

Controls and Settings

Access all functions via the electronic control panel.

Control Panel: POWER, MODE (Continuous/Normal/Turbo), HUMIDITY SET (Up/Down arrows), TIMER, FILTER RESET indicator.

Display Icons: Power, Bucket Full, Defrost, Filter Clean, Set Humidity, Timer, Turbo Mode.

Settings: Humidity Set Point (40%-80%), Mode (Continuous runs until tank is full/target met; Normal cycles fan; Turbo for max speed), Timer (1-24 hours for auto on/off). Filter Reset: Press and hold FILTER button for 3 seconds after cleaning to reset the reminder light.

Operation Modes

Select the mode best suited for your environment.

  1. Normal Mode: The unit cycles the compressor and fan to maintain the set humidity level. Recommended for standard use.
  2. Continuous Mode: The unit runs continuously until the bucket is full or the target humidity is reached, ignoring the set point. Use for very damp conditions.
  3. Turbo Mode: Fan runs at maximum speed for fastest dehumidification. Press the MODE button to select.
  4. Auto-Defrost: Automatically activates when frost is detected on the coils, pausing dehumidification until coils are clear.

Tip: For energy efficiency, set the humidity to 50-55% and use Normal mode in living areas.

Maintenance & Cleaning

Unplug the unit before any maintenance.

  1. Emptying the Bucket: When the "Bucket Full" light comes on, pull the bucket straight out, carry it by the handle, and empty it. Replace securely.
  2. Cleaning the Air Filter: Remove the filter every 2 weeks. Wash with warm, soapy water, rinse, and let dry completely before reinstalling. Reset the FILTER light.
  3. Cleaning the Exterior: Wipe the cabinet with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  4. End-of-Season Cleaning: For storage, run the unit in Fan Only mode for a few hours to dry the interior before storing.

CAUTION! Never immerse the unit in water. Do not operate without the air filter installed.

Storage Instructions

If not using for an extended period:

  1. Unplug the unit.
  2. Empty and dry the water bucket completely.
  3. Clean the air filter and let it dry.
  4. Coil the power cord neatly.
  5. Store the unit upright in a cool, dry place. Cover it to prevent dust accumulation.

WARNING! Store in an area where the temperature will not fall below freezing.

Regulatory Information

This dehumidifier complies with relevant U.S. safety and performance standards. The refrigerant system is sealed. Servicing should only be performed by qualified personnel. For support in the United States and Canada, contact Danby at 1-800-263-2629 or visit www.danby.com.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not startNo power / Bucket not seatedEnsure unit is plugged in and outlet is live. Remove and reinsert the water bucket firmly.
Little or no water collectionLow humidity / Cold room / Filter dirtyRoom may already be dry. Ensure room temp is above 41°F (5°C). Clean the air filter.
"Bucket Full" light is on, but bucket is emptyFloat switch stuckUnplug unit. Remove bucket, check for obstruction around the float switch, and clear any debris.
Unit is noisy or vibratingUneven floor / Loose partsPlace on a firm, level surface. Ensure all panels and the bucket are securely in place.
Error Code "E1" or "E2" on displaySensor fault / System errorUnplug the unit for 5 minutes, then restart. If code persists, contact Danby Customer Service.
Ice on coils (in low temps)Normal operation in coldAuto-defrost should activate. If ice persists, turn unit off and let it thaw. Use only in recommended temp range.

Reset: Unplug the unit for 5 minutes to perform a full system reset.

Service: 1-800-263-2629; www.danby.com