The Danby DDR050BJPWDB-ME is a 50-pint capacity dehumidifier designed for residential use, featuring electronic controls, a continuous drain option, auto-defrost, a built-in humidistat, a 24-hour timer, a washable air filter, and a full bucket alert with auto-shutoff. It operates on 115V AC, 60Hz. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Electronic Control Panel, Water Collection Bucket, Continuous Drain Hose Port, Air Filter, Casters for Mobility, and Handle.
| Feature | Description |
|---|---|
| Electronic Controls | Digital display with touch buttons for settings |
| Humidistat | Automatic humidity level control |
| 24-Hour Timer | Programmable on/off cycles |
| Continuous Drain Option | Port for connecting a hose (not included) |
| Auto-Defrost | Prevents coil freezing in low temperatures |
| Full Bucket Alert & Auto-Shutoff | Alerts when bucket is full and stops operation |
| Washable Air Filter | Captures airborne particles; can be cleaned |
| POWER Button | Turns dehumidifier on/off |
| MODE Button | Selects between Continuous, Auto, and Timer modes |
| UP/DOWN Buttons | Adjusts desired humidity level and timer settings |
Unpack and inspect contents. Place on a level, stable floor.
WARNING! Do not place in closets or confined spaces. Ensure the room temperature is between 41°F (5°C) and 95°F (35°C) for optimal operation.
Plug in the unit; the control panel will illuminate.
CAUTION! Allow the unit to stand upright for at least 24 hours if it was tilted or laid on its side during transport.
Access all functions via the electronic control panel on top of the unit.
Display Icons: Power, Bucket Full, Defrost, Continuous Mode, Auto Mode, Timer Set.
Buttons: POWER, MODE, UP (+), DOWN (-).
Humidity Setting: Range from 35% to 85% RH. In Auto Mode, the unit cycles on/off to maintain this level.
Timer: Can be set from 1 to 24 hours for automatic shut-off or start delay.
Filter Reset Indicator: Flashes after 250 hours of operation as a reminder to clean the air filter.
Three primary operating modes are available.
Note: The Auto-Defrost function operates automatically in all modes when low coil temperature is detected.
Unplug the unit before performing any maintenance.
Two methods for water removal.
Tip: For basement use, the continuous drain is highly recommended.
Prepare the unit for long-term storage.
CAUTION! Do not store the unit on its side or upside down. Never place heavy objects on top of it.
This appliance complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. This product contains refrigerant R410a. For proper disposal at end of life, consult local environmental regulations. For support, visit www.danby.com or contact Danby Customer Service at 1-800-263-2629.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit does not start | No power / Bucket not seated | Ensure unit is plugged in and outlet is live. Remove and reinsert bucket firmly. |
| Red "Bucket Full" light is on | Bucket is full or float is stuck | Empty bucket. Check for obstructions preventing the float from moving freely. |
| Little or no water collection | Low humidity / Cold room / Dirty filter | Room humidity may already be low. Ensure room temp is above 41°F (5°C). Clean the air filter. |
| Unit runs but air feels warm | Normal during auto-defrost cycle | This is normal operation in low temperatures. The defrost cycle lasts up to 10 minutes. |
| Unusual noise or vibration | Unit not level / Loose parts | Place unit on a hard, level surface. Ensure casters are locked and internal components are secure. |
| Error Code "E1" or "E2" | Sensor fault | Unplug unit for 5 minutes, then restart. If error persists, contact customer service. |
Reset: Unplug the unit for 5 minutes to reset the electronic control system.
Service: 1-800-263-2629; www.danby.com