Danby DDR050BJPWDB-ME Dehumidifier Manual

The Danby DDR050BJPWDB-ME is a 50-pint capacity dehumidifier designed for residential use, featuring electronic controls, a continuous drain option, auto-defrost, a built-in humidistat, a 24-hour timer, a washable air filter, and a full bucket alert with auto-shutoff. It operates on 115V AC, 60Hz. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic Control Panel, Water Collection Bucket, Continuous Drain Hose Port, Air Filter, Casters for Mobility, and Handle.

FeatureDescription
Electronic ControlsDigital display with touch buttons for settings
HumidistatAutomatic humidity level control
24-Hour TimerProgrammable on/off cycles
Continuous Drain OptionPort for connecting a hose (not included)
Auto-DefrostPrevents coil freezing in low temperatures
Full Bucket Alert & Auto-ShutoffAlerts when bucket is full and stops operation
Washable Air FilterCaptures airborne particles; can be cleaned
POWER ButtonTurns dehumidifier on/off
MODE ButtonSelects between Continuous, Auto, and Timer modes
UP/DOWN ButtonsAdjusts desired humidity level and timer settings

Installation & Placement

Unpack and inspect contents. Place on a level, stable floor.

  1. Choose Location: Place in center of room, at least 12 inches from walls and furniture for proper airflow.
  2. Check Air Vents: Ensure air intake and discharge vents are unobstructed.
  3. Install Casters: Attach casters to base for mobility (if not pre-installed).
  4. Plug into a dedicated 115V AC outlet. Do not use an extension cord.

WARNING! Do not place in closets or confined spaces. Ensure the room temperature is between 41°F (5°C) and 95°F (35°C) for optimal operation.

First-Time Setup

Plug in the unit; the control panel will illuminate.

  1. Insert Bucket: Ensure the water collection bucket is correctly seated.
  2. Power On: Press the POWER button.
  3. Set Humidity: Use the UP/DOWN buttons to set your desired humidity level (40%-60% recommended).
  4. Select Mode: Press MODE to choose between Continuous, Auto (humidistat-controlled), or Timer mode.
  5. Set Timer (Optional): In Timer mode, use UP/DOWN to set the operating duration.

CAUTION! Allow the unit to stand upright for at least 24 hours if it was tilted or laid on its side during transport.

Specifications

Controls and Settings

Access all functions via the electronic control panel on top of the unit.

Display Icons: Power, Bucket Full, Defrost, Continuous Mode, Auto Mode, Timer Set.

Buttons: POWER, MODE, UP (+), DOWN (-).

Humidity Setting: Range from 35% to 85% RH. In Auto Mode, the unit cycles on/off to maintain this level.

Timer: Can be set from 1 to 24 hours for automatic shut-off or start delay.

Filter Reset Indicator: Flashes after 250 hours of operation as a reminder to clean the air filter.

Operation Modes

Three primary operating modes are available.

  1. Continuous Mode: Runs constantly until turned off or the bucket is full. Ignores humidistat setting.
  2. Auto Mode (Default): Unit automatically turns on/off based on the humidistat setting to maintain desired humidity.
  3. Timer Mode: Set a duration (1-24 hrs) for the unit to run before automatically shutting off. Can also be used as a delayed start.

Note: The Auto-Defrost function operates automatically in all modes when low coil temperature is detected.

Maintenance & Cleaning

Unplug the unit before performing any maintenance.

  1. Emptying the Bucket: Remove bucket when full (indicator light will illuminate). Empty water, dry the interior, and reinsert firmly.
  2. Cleaning the Air Filter: Remove filter every 2 weeks or when the Filter Reset light flashes. Wash with warm water and mild detergent. Let dry completely before reinstalling. Press and hold the MODE button for 3 seconds to reset the filter timer.
  3. Cleaning the Exterior: Wipe cabinet with a soft, damp cloth. Do not use abrasive cleaners.
  4. End-of-Season Cleaning: Run the unit in Continuous Mode with the bucket in place for a few hours to dry internal components before storage.

Drainage Options

Two methods for water removal.

  1. Bucket Collection: Standard method. Monitor the Full Bucket indicator.
  2. Continuous Drain:
    • Locate the drain port on the back of the unit.
    • Remove the port plug.
    • Connect a standard garden hose (¾" inner diameter, not included). Ensure hose runs downward without kinks.
    • Place the hose end into a floor drain or suitable container.
    • The bucket must remain in place for the float switch to operate, but it will not fill.

Tip: For basement use, the continuous drain is highly recommended.

Care & Storage

Prepare the unit for long-term storage.

  1. Unplug the power cord.
  2. Empty and clean the water bucket. Let it air dry.
  3. Clean the air filter and let it dry completely.
  4. Coil the power cord neatly.
  5. Store the unit upright in a cool, dry place. Cover it to prevent dust accumulation.

CAUTION! Do not store the unit on its side or upside down. Never place heavy objects on top of it.

Regulatory Information

This appliance complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. This product contains refrigerant R410a. For proper disposal at end of life, consult local environmental regulations. For support, visit www.danby.com or contact Danby Customer Service at 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not startNo power / Bucket not seatedEnsure unit is plugged in and outlet is live. Remove and reinsert bucket firmly.
Red "Bucket Full" light is onBucket is full or float is stuckEmpty bucket. Check for obstructions preventing the float from moving freely.
Little or no water collectionLow humidity / Cold room / Dirty filterRoom humidity may already be low. Ensure room temp is above 41°F (5°C). Clean the air filter.
Unit runs but air feels warmNormal during auto-defrost cycleThis is normal operation in low temperatures. The defrost cycle lasts up to 10 minutes.
Unusual noise or vibrationUnit not level / Loose partsPlace unit on a hard, level surface. Ensure casters are locked and internal components are secure.
Error Code "E1" or "E2"Sensor faultUnplug unit for 5 minutes, then restart. If error persists, contact customer service.

Reset: Unplug the unit for 5 minutes to reset the electronic control system.

Service: 1-800-263-2629; www.danby.com