Danby DDR050BJWDB Dehumidifier Manual

The Danby DDR050BJWDB is a 50-pint capacity dehumidifier designed for residential use. It features an electronic control panel with adjustable humidity settings, a continuous drain option, a full bucket alert with auto-shutoff, a washable air filter, a 24-hour timer, and turbo mode for faster moisture removal. Suitable for rooms up to 3000 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Modes 7. Maintenance & Cleaning 8. Storage Instructions 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Electronic control panel, 50-pint water bucket, Continuous drain hose port, Washable air filter, Casters for mobility, Handle for carrying.

FeatureDescription
Capacity50 pints per day (at 80°F, 60% RH)
Control PanelDigital display with touch controls
Humidity SettingAdjustable from 35% to 85% relative humidity
Continuous DrainHose connection for unattended operation
Full Bucket AlertIndicator light and auto-shutoff when bucket is full
Timer24-hour programmable on/off timer
Turbo ModeIncreases fan speed for faster dehumidification
Air FilterWashable, removable filter for improved air quality
MobilityFour casters and top handle for easy movement
Power Cord6-foot length with storage wrap

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Remove packaging: Take off all tape and protective materials.
  2. Position unit: Place at least 12 inches from walls and furniture for proper airflow.
  3. Check level: Ensure unit is level for optimal bucket operation and water collection.
  4. Install drain hose (optional): Attach 5/8" ID hose to drain port for continuous drainage.
  5. Plug into grounded 120V AC outlet.

WARNING! Do not place in tight enclosures or near heat sources. Ensure proper ventilation around the unit.

First-Time Setup

Plug in unit; control panel will illuminate.

  1. Install water bucket: Slide bucket into place until it clicks.
  2. Set humidity level: Press HUMIDITY button to select desired RH (start with 50%).
  3. Select mode: Choose between Normal, Turbo, or Timer mode.
  4. Check filter: Ensure air filter is clean and properly seated.
  5. For continuous drain: Connect hose and ensure downward slope for gravity flow.

CAUTION! Handle bucket with care to avoid spills. Do not operate without bucket properly installed.

Specifications

Controls and Settings

Control Panel: POWER, MODE, HUMIDITY, TIMER, FILTER RESET.

Display Indicators: Current humidity, Set humidity, Timer, Bucket full, Filter clean, Turbo mode.

Humidity Setting: Adjust from 35% to 85% in 5% increments. Mode Selection: Normal (standard operation), Turbo (high-speed dehumidification), Timer (programmed operation). Timer: Set 1-24 hours for automatic start/stop. Filter Alert: FILTER light illuminates after 250 hours of operation; clean filter and press FILTER RESET.

Operating Modes

Normal Mode: Standard dehumidification with adjustable fan speed. Turbo Mode: Maximum moisture removal for damp conditions. Timer Mode: Program unit to turn on/off at specific times.

  1. Press POWER to turn unit on.
  2. Press MODE to cycle through Normal, Turbo, Timer.
  3. In Timer mode, use +/- buttons to set hours.
  4. Unit will run until humidity setpoint is reached, then enter standby.
  5. Empty bucket when FULL light illuminates or use continuous drain.

Tip: For energy efficiency, set humidity to 50-55% for most conditions.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean air filter: Remove every 2 weeks, wash with warm water, dry completely before reinstalling.
  2. Empty water bucket: Regularly empty and clean with mild detergent; rinse thoroughly.
  3. Clean exterior: Wipe with soft, damp cloth; do not use abrasive cleaners.
  4. Check drain hose: Ensure continuous drain hose is clear of obstructions.
  5. Off-season storage: Follow storage instructions when not in use for extended periods.

WARNING! Always unplug unit before cleaning. Never immerse in water or use harsh chemicals.

Storage Instructions

When storing unit for extended periods (winter months):

  1. Unplug unit and empty water bucket completely.
  2. Clean air filter and bucket as described in maintenance section.
  3. Run unit in Fan Only mode for 30 minutes to dry internal components.
  4. Coil power cord and secure with wrap.
  5. Store in cool, dry place protected from dust.
  6. Cover unit to prevent dust accumulation.

CAUTION! Store in upright position. Do not place heavy objects on top.

Regulatory Information

UL Listed: Meets UL standard 474. Energy Star: Certified for energy efficiency. EPA Refrigerant: Uses R-410A, an environmentally friendly refrigerant. FCC Compliance: Class B digital device; complies with interference limits. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onNo powerCheck outlet; ensure plug is fully inserted; test outlet with another device.
Not removing moistureRoom temperature too lowOperate only above 41°F; move to warmer area if needed.
Bucket full light onBucket full or not seatedEmpty bucket; ensure it's properly inserted and clicked in place.
Water leakingBucket overflow or hose issueCheck bucket seating; ensure continuous drain hose is properly connected and sloping downward.
Loud noiseUneven surface or foreign objectPlace on level surface; check for objects near fan; clean air filter.
Filter light onDirty filterClean air filter thoroughly; press and hold FILTER RESET for 3 seconds.
Ice on coilsLow temperature or dirty filterTurn unit off and let ice melt; clean filter; ensure room temp is above 41°F.

Reset: Unplug for 5 minutes to reset electronic controls.

Service: 1-800-263-2629; www.danby.com