Danby DDR050BLPBDB Dehumidifier Manual

The Danby DDR050BLPBDB is a 50-pint capacity dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage option, auto-restart after power interruption, washable air filter, digital controls with LED display, 24-hour timer, full bucket alert with auto-shutoff, and energy-efficient operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Instructions 7. Maintenance 8. Care & Cleaning 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Digital control panel, Water collection bucket, Air filter, Continuous drainage port, Casters for mobility, Power cord.

FeatureDescription
Capacity50 pints per day (at 80°F, 60% RH)
Humidity ControlAutomatic with adjustable set point (35%-85%)
Digital DisplayLED showing humidity level and settings
Timer24-hour programmable on/off timer
Continuous DrainageGarden hose connection for continuous water removal
Auto RestartResumes previous settings after power interruption
Full Bucket AlertIndicator light and auto-shutoff when bucket is full
Washable FilterRemovable and washable air filter
MobilityFour casters for easy movement
Energy EfficiencyEnergy Star certified

Installation

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place at least 12 inches from walls and furniture for proper airflow.
  2. Bucket installation: Ensure water collection bucket is properly seated.
  3. Continuous drainage (optional): Connect standard garden hose to drainage port.
  4. Power connection: Plug into dedicated 115V AC, 60Hz outlet.

WARNING! Do not use extension cords. Ensure proper grounding. Keep away from water sources.

First-Time Setup

Plug in unit; control panel will illuminate.

  1. Set desired humidity: Press HUMIDITY button to select level (35%-85%).
  2. Select fan speed: Choose LOW or HIGH using FAN button.
  3. Set timer (optional): Use TIMER button to program operation schedule.
  4. Check filter: Ensure air filter is clean and properly installed.

CAUTION! Allow unit to stand upright for 24 hours if transported horizontally.

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, FILTER RESET.

Display Indicators: Current humidity, Set humidity, Timer status, Filter alert, Full bucket alert.

Humidity Control: Adjust between 35%-85% in 5% increments. Fan Speed: LOW for quiet operation, HIGH for maximum moisture removal. Timer: Program unit to turn on/off up to 24 hours in advance. Filter Reset: Press after cleaning filter to reset alert. Auto Defrost: Automatically activates when coil temperature drops below 41°F.

Operating Instructions

Normal Operation: Unit runs until desired humidity is reached, then cycles on/off automatically.

  1. Power on: Press POWER button.
  2. Set humidity: Use HUMIDITY button to select desired level.
  3. Monitor: Display shows current room humidity.
  4. Water removal: Empty bucket when FULL indicator lights or use continuous drainage.
  5. Power off: Press POWER button when not in use.

Tip: For best results, keep doors and windows closed in area being dehumidified.

Maintenance

Regular maintenance ensures optimal performance and longevity.

  1. Clean air filter: Remove and wash every 2 weeks or as needed.
  2. Empty water bucket: Regularly empty and clean with mild detergent.
  3. Clean exterior: Wipe with damp cloth; never use harsh chemicals.
  4. Check drainage: Ensure continuous drainage hose is clear if used.
  5. Off-season storage: Empty completely, clean, and store in dry location.

WARNING! Always unplug unit before performing any maintenance.

Care & Cleaning

Unplug before cleaning. Use soft, damp cloth only; do not immerse in water.

CAUTION! Do not use gasoline, thinners, or abrasive cleaners. Keep electrical components dry.

Regulatory Information

UL Listed. Energy Star certified. FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningNo power/bucket fullCheck power connection; empty water bucket; reset circuit breaker.
Poor dehumidificationDirty filter/extreme conditionsClean air filter; ensure room temperature above 41°F; close doors/windows.
Water leakageImproper bucket placementEnsure bucket is properly seated; check for cracks; ensure continuous drainage hose is connected securely.
Loud noiseUneven surface/loose partsPlace on level surface; check for loose components; ensure nothing is touching fan.
Display not workingPower issueCheck power source; unplug for 10 minutes then restart.

Reset: Unplug for 10 minutes to reset electronic controls.

Service: 1-800-263-2629; www.danby.com

Danby DDR050BLPBDB Dehumidifier Manual © - All Rights Reserved 2025