Danby DDR050CBLPMBDB-RF Dehumidifier Manual

The Danby DDR050CBLPMBDB-RF is a 50-pint dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage option, electronic controls with digital display, auto-restart function, washable air filter, and a built-in pump for vertical water removal. It operates on 115V/60Hz and is ideal for areas up to 3000 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Setup 3. First-Time Operation 4. Specifications 5. Controls and Settings 6. Drainage Options 7. Maintenance & Cleaning 8. Energy Saving Tips 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Electronic control panel, Digital humidity display, Built-in condensate pump, Continuous drain hose, Washable air filter, Full bucket alert, Auto-defrost function.

FeatureDescription
Dehumidification Capacity50 pints per day (at 80°F, 60% RH)
Built-in PumpLifts water vertically up to 15 feet
Continuous DrainageOption for hose connection (included)
Electronic ControlsDigital display with humidity readout
Auto Humidity ControlSet desired humidity level (35%-85%)
Washable Air FilterRemovable for easy cleaning
Auto-RestartResumes previous settings after power outage
Full Bucket AlertIndicator light and auto shut-off
Timer Function24-hour programmable on/off timer
Auto-DefrostPrevents coil freezing in low temperatures

Installation & Setup

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place unit at least 12 inches from walls and furniture for proper airflow.
  2. Power Connection: Plug directly into 115V grounded outlet. Do not use extension cords.
  3. Bucket Installation: Ensure water collection bucket is properly seated.
  4. Drainage Setup: For continuous drainage, attach hose to drain port and route to floor drain.
  5. Filter Check: Verify air filter is clean and properly installed.

WARNING! Do not operate in temperatures below 41°F (5°C). Ensure unit is upright for 24 hours before first use if transported on its side.

First-Time Operation

Power on dehumidifier; follow control panel prompts.

  1. Set Humidity Level: Press HUMIDITY button to set desired level (recommended 45-50%).
  2. Select Fan Speed: Choose HIGH or LOW fan setting for desired air flow.
  3. Timer Setup: Use TIMER button to program automatic start/stop times if needed.
  4. Pump Operation: Ensure pump switch is ON if using vertical drainage.
  5. Monitor Display: Check current room humidity on digital display.

CAUTION! Do not block air intake or exhaust grilles. Keep children away from unit during operation.

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, PUMP ON/OFF, FILTER RESET.

Display Indicators: Current humidity, Set humidity, Timer status, Filter alert, Full bucket, Pump status.

Humidity Control: Adjust between 35%-85% in 5% increments. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: Program up to 24 hours for automatic operation. Pump Control: Switch between bucket collection and continuous pump drainage. Filter Reset: Press after cleaning air filter to reset maintenance indicator.

Drainage Options

Three drainage methods: Bucket collection, Gravity drain, Pump drainage.

  1. Bucket Method: Unit automatically shuts off when bucket is full (indicator light).
  2. Gravity Drain: Connect hose to drain port, route to floor drain (unit must be higher than drain).
  3. Pump Drainage: Enable pump switch, connect hose, pump lifts water vertically up to 15 feet.

Tip: For continuous operation, use gravity or pump drainage to avoid frequent bucket emptying.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Air Filter: Clean every 2 weeks with vacuum or warm water. Allow to dry completely before reinstalling.
  2. Bucket Cleaning: Empty and clean bucket monthly with mild detergent to prevent mold.
  3. Exterior Cleaning: Wipe cabinet with damp cloth. Do not use harsh chemicals.
  4. Coil Inspection: Check evaporator coil annually for dust buildup (professional service recommended).
  5. Off-Season Storage: Empty all water, clean components, store in upright position in dry area.

WARNING! Always unplug unit before cleaning. Never immerse in water or use steam cleaners.

Energy Saving Tips

Close windows and doors during operation. Set humidity to 45-50% for optimal efficiency. Use timer to run during peak humidity hours only. Ensure proper room sealing to prevent outside air infiltration. Clean filter regularly to maintain airflow efficiency.

Regulatory Information

UL Listed for safety. EPA compliant refrigerant (R410A). Energy Star certified. This product meets applicable DOE energy efficiency standards. For warranty information and service, visit www.danby.com or contact 1-800-263-2629. Manufactured for Danby Products Inc.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue, Full bucketCheck power connection; Empty bucket; Reset circuit breaker.
Low moisture removalDirty filter, Low temperatureClean air filter; Ensure room temp above 41°F (5°C).
Water leakageImproper hose connectionCheck all connections; Ensure bucket properly seated.
Pump not workingSwitch setting, ClogEnsure pump switch ON; Check hose for kinks/clogs.
Loud noiseUneven surface, Loose partsPlace on level surface; Check for loose components.
Display not workingPower issueCheck power supply; Unplug for 5 minutes then restart.
Ice on coilsLow temperatureAuto-defrost should activate; Move to warmer area.
Filter light onDirty filterClean air filter; Press FILTER RESET button.

Reset: Unplug for 5 minutes to reset electronic controls.

Service: 1-800-263-2629; www.danby.com

Danby DDR050CBLPMBDB-RF Dehumidifier Manual © - All Rights Reserved 2025