Danby DDR050EACWDB Dehumidifier Manual

The Danby DDR050EACWDB is a 50-pint capacity dehumidifier designed for residential use. It features electronic controls, a continuous drain option, auto-restart, a washable air filter, and a built-in humidistat for precise moisture control. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drainage 7. Operating Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic control panel, Water tank with full indicator, Continuous drain hose connection, Washable air filter, Auto-defrost function, and Built-in humidistat.

FeatureDescription
Capacity50 pints per day (at 60°F, 60% RH)
Control PanelElectronic touch controls with digital display
Water TankRemovable bucket with full alert and auto shut-off
Continuous DrainHose connection for unattended operation
Air FilterWashable filter to maintain air quality
Auto-RestartResumes previous settings after power interruption
HumidistatAdjustable from 35% to 85% relative humidity
Timer24-hour programmable on/off timer
Auto-DefrostPrevents coil freezing in low temperatures
Power Cord6-foot cord with storage wrap

Installation

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place unit at least 12 inches from walls and furniture for proper airflow.
  2. Check filter: Ensure air filter is properly installed before operation.
  3. Power connection: Plug into a dedicated 115V AC, 60Hz outlet.
  4. Drain setup: For continuous drainage, attach hose to drain port and route to floor drain or sink.

WARNING! Do not place in areas with high dust or chemical fumes. Ensure the power outlet is properly grounded.

First-Time Setup

Plug in the unit; follow initial setup steps.

  1. Set humidity level: Press HUMIDITY button to set desired level (recommended 45-50%).
  2. Select mode: Choose from CONTINUOUS, AUTO, or DRY modes using MODE button.
  3. Set timer (optional): Use TIMER button to program on/off cycles.
  4. Check operation: Unit should start within 3 minutes; compressor may cycle on/off.

CAUTION! Allow unit to stand upright for 24 hours if transported on its side.

Specifications

Controls and Settings

Control Panel: POWER, MODE, HUMIDITY, FAN SPEED, TIMER, FILTER RESET.

Display Indicators: Current humidity, Set humidity, Tank full, Filter clean, Timer, Mode icons.

Modes: CONTINUOUS (runs constantly), AUTO (cycles based on humidistat), DRY (for laundry rooms). Fan Speed: HIGH or LOW. Timer: Set 1-24 hours for automatic start/stop. Filter Reset: Press after cleaning filter. Humidity Control: Adjust in 5% increments from 35% to 85%.

Connecting Drainage

Two drainage options: Manual (bucket) or Continuous (hose).

  1. Manual: Empty bucket when FULL light illuminates.
  2. Continuous: Attach 5/8" ID hose (not included) to drain port. Ensure hose runs downward without kinks.
  3. Gravity drain: Place unit higher than drain point for proper flow.

Tip: For basement use, continuous drainage is recommended to prevent overflow.

Operating Modes

Select mode based on your needs.

  1. AUTO Mode: Unit runs until set humidity is reached, then cycles on/off automatically.
  2. CONTINUOUS Mode: Runs continuously regardless of humidity level.
  3. DRY Mode: Optimized for drying laundry rooms or damp areas.
  4. Timer Operation: Set unit to turn on/off at specific times.
  5. Fan Only: Press FAN button to circulate air without dehumidifying.

WARNING! Do not operate below 41°F (5°C) without auto-defrost feature enabled.

Maintenance

Regular maintenance ensures optimal performance.

Care & Cleaning

Unplug before cleaning. Use soft, damp cloth for exterior. Do not use abrasive cleaners.

CAUTION! Never immerse unit in water. Do not use chemicals on plastic parts.

Regulatory Information

UL Listed. Complies with FCC Part 15 Subpart B. Energy Star certified. Manufactured for Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629. This product contains refrigerant that must be recovered by certified technicians.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/full tankCheck power outlet; ensure tank is empty and properly seated.
Low dehumidificationDirty filter/low tempClean air filter; room temperature may be below 41°F.
Water leakageMisaligned tank/hoseEnsure tank is properly inserted; check hose connections.
Loud noiseUneven surface/fanPlace on level floor; check for obstructions in fan area.
Display not workingPower interruptionUnplug for 10 minutes, then restart; check circuit breaker.
Ice on coilsLow temperatureAuto-defrost should activate; move to warmer area if persistent.

Reset: Unplug for 10 minutes to reset electronic controls.

Service: 1-800-263-2629; www.danby.com