Danby DDR060BDCWDB Dehumidifier Manual

The Danby DDR060BDCWDB is a 60-pint dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage option, washable air filter, digital display with humidity readout, 24-hour timer, auto-restart after power interruption, and energy-efficient operation. Suitable for areas up to 3000 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drainage 7. Operation Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, removable water bucket with full indicator, continuous drain hose connection, washable air filter, caster wheels for mobility, and auto-defrost function.

FeatureDescription
Digital DisplayShows current humidity level and settings
Humidity ControlAdjustable from 35% to 85% relative humidity
24-Hour TimerProgram on/off times for energy savings
Continuous DrainOption for hose connection (not included)
Auto-RestartResumes previous settings after power outage
Full Bucket AlertLight indicator and auto shut-off when full
Washable FilterRemovable air filter for easy cleaning
Caster WheelsFour wheels for easy room-to-room movement
Auto-DefrostPrevents coil freezing in low temperatures
Energy EfficientENERGY STAR® certified model

Installation

Unpack and inspect contents. Place on level surface.

  1. Position unit: Allow at least 12 inches clearance on all sides for proper airflow.
  2. Install filter: Ensure washable filter is properly seated in front grille.
  3. Check bucket: Ensure water bucket is correctly inserted and locked.
  4. Plug into dedicated 115V AC outlet.

WARNING! Do not use extension cords. Ensure outlet is properly grounded. Keep away from heat sources.

First-Time Setup

Plug in unit; control panel will illuminate.

  1. Set humidity level: Press HUMIDITY button to select desired level (45-50% recommended).
  2. Select mode: Choose between CONTINUOUS or AUTO mode based on needs.
  3. Set timer (optional): Press TIMER to program operation schedule.
  4. For continuous drainage: Connect hose to drain port before operation.

CAUTION! Operate only in temperatures between 41°F and 95°F. Do not block air intake or exhaust.

Specifications

Controls and Settings

Control Panel: POWER, MODE, HUMIDITY, TIMER, FAN SPEED (LOW/HIGH).

Display Icons: Power, Bucket Full, Defrost, Timer, Continuous Mode, Fan Speed.

Modes: CONTINUOUS (runs constantly), AUTO (maintains set humidity), DRY CLOTHES (increased fan speed). Humidity Setting: Adjustable 35-85% in 5% increments. Timer: 1-24 hours programmable. Fan Speed: LOW for quiet operation, HIGH for maximum moisture removal.

Connecting Drainage

Continuous drain option for unattended operation.

  1. Turn off and unplug unit.
  2. Remove drain plug from back of unit.
  3. Connect 5/8" ID hose (not included) to drain port.
  4. Route hose to floor drain or suitable drainage area.
  5. Ensure hose has downward slope without kinks.

Tip: When using continuous drain, bucket should remain in place. Check hose regularly for clogs.

Operation Modes

Three operation modes for different needs.

  1. AUTO Mode: Unit cycles on/off to maintain set humidity level.
  2. CONTINUOUS Mode: Runs continuously regardless of humidity level.
  3. DRY CLOTHES Mode: Higher fan speed for drying laundry in enclosed space.
  4. Timer Operation: Set 1-24 hours for automatic start/stop.
  5. Auto-Defrost: Automatically activates when coil temperature drops below 41°F.

WARNING! Do not use in unheated spaces below 41°F. Empty bucket before moving unit.

Maintenance

Regular maintenance ensures optimal performance.

  1. Clean filter every 2 weeks: Remove, wash with mild detergent, dry completely.
  2. Empty bucket: When full indicator lights, remove and empty bucket.
  3. Clean exterior: Wipe with damp cloth, then dry.
  4. End-of-season: Empty completely, clean filter, store upright in dry location.

Note: Do not operate without filter. Replace filter if damaged.

Care & Cleaning

Unplug before any cleaning. Use only mild detergent and water.

CAUTION! Never immerse unit in water. Do not use harsh chemicals, gasoline, or solvents. Keep electrical components dry.

Regulatory Information

This dehumidifier complies with FCC Part 15 Subpart B. This device complies with Industry Canada license-exempt RSS standard(s). Copyright © Danby Products Inc. ENERGY STAR® is a registered trademark of the U.S. Environmental Protection Agency. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/bucket fullCheck power outlet; empty bucket; ensure bucket properly seated.
Poor moisture removalFilter/door/room tempClean filter; close doors/windows; ensure room temp above 41°F.
Water leakageBucket/hose connectionEnsure bucket properly inserted; check hose for kinks/leaks.
Loud noiseUneven surface/fanPlace on level surface; check for foreign objects in fan area.
Display not workingPower/control issueUnplug for 10 minutes, then restart; check circuit breaker.

Reset: Unplug for 10 minutes to reset electronic controls.

Service: 1-800-263-2629; www.danby.com