Danby DDR060BDWDB Dehumidifier Manual

The Danby DDR060BDWDB is a 60-pint dehumidifier designed for residential use, featuring automatic humidity control, a continuous drain option, a washable air filter, a full-bucket alert with auto-shutoff, a 24-hour timer, and electronic controls with LED display. It operates on 115V/60Hz and is suitable for areas up to 3000 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Draining Options 9. Safety Information 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic control panel with LED display, removable water bucket with handle, washable air filter, continuous drain hose connection, casters for mobility, and adjustable humidity settings.

FeatureDescription
Capacity60 pints per day (at 80°F, 60% RH)
Humidity ControlAdjustable from 35% to 80% relative humidity
Water BucketRemovable 2.1-gallon bucket with full indicator and auto-shutoff
Continuous DrainHose connection for unattended operation
Air FilterWashable mesh filter for improved air quality
Timer24-hour programmable on/off timer
ControlsElectronic touchpad with LED display
MobilityFour swivel casters for easy movement
Auto RestartResumes previous settings after power interruption
Operating Conditions41°F to 95°F (5°C to 35°C)

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place at least 12 inches from walls and furniture for proper airflow.
  2. Level Surface: Ensure unit is level to prevent water leakage.
  3. Environment: Operate in enclosed areas between 41°F and 95°F.
  4. Power Connection: Plug directly into a grounded 115V outlet; avoid extension cords.

WARNING! Do not operate in temperatures below 41°F to prevent coil freezing. Ensure adequate ventilation around the unit.

First-Time Setup

Plug in the dehumidifier; the control panel will illuminate.

  1. Install the air filter: Ensure the washable filter is properly seated in the rear grille.
  2. Set humidity level: Press the HUMIDITY button to select desired level (recommended 45-50%).
  3. Select fan speed: Choose HIGH or LOW using the FAN button.
  4. Bucket check: Ensure the water bucket is correctly inserted until it clicks.
  5. For continuous drain: Attach a standard garden hose (¾") to the drain port if desired.

CAUTION! Handle the water bucket with care to avoid spills. Do not operate without the air filter installed.

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, FILTER ALERT, BUCKET FULL indicator.

LED Display: Shows current humidity, set humidity, timer status, filter alert, and bucket full indicator.

Humidity Control: Adjust from 35% to 80% in 5% increments. Fan Speed: HIGH for maximum dehumidification, LOW for quiet operation. Timer: Set 1-24 hours for automatic start/stop. Filter Alert: LED illuminates when filter needs cleaning. Auto Shutoff: Unit stops when bucket is full; "FULL" indicator lights.

Operation Modes

Normal Mode: Set desired humidity; unit runs until target is reached, then cycles on/off automatically. Continuous Mode: Set humidity to "CONT" for constant operation (used for very damp areas). Timer Mode: Program unit to turn on/off at specific times.

  1. Press POWER to turn on.
  2. Set humidity using HUMIDITY buttons.
  3. Select fan speed (HIGH/LOW).
  4. For timer, press TIMER and use arrows to set hours.
  5. Unit will run until humidity setpoint is met or bucket is full.

Tip: For energy savings, set humidity to 50% and use the timer to run during peak humidity hours.

Maintenance & Cleaning

Unplug unit before any maintenance.

  1. Cleaning the bucket: Empty and wash with mild detergent monthly; rinse thoroughly.
  2. Cleaning the filter: Remove filter every 2 weeks, wash with warm water, let dry completely before reinstalling.
  3. Exterior cleaning: Wipe cabinet with soft, damp cloth; do not use abrasive cleaners.
  4. End-of-season storage: Empty bucket, clean filter, let unit dry, coil with power cord, store in upright position.

WARNING! Never immerse unit in water. Do not operate without the filter installed.

Draining Options

Bucket Method: Unit stops when bucket is full; remove, empty, and replace. Continuous Drain: Attach hose to drain port for uninterrupted operation.

  1. Locate drain port on back of unit.
  2. Remove drain plug and save.
  3. Connect standard ¾" garden hose (not included).
  4. Route hose to floor drain or suitable outlet.
  5. Ensure hose has downward slope to prevent water backup.

CAUTION! Do not kink or elevate drain hose above drain port level.

Safety Information

Read all instructions before use. Always plug into grounded outlet. Do not use extension cord. Keep children away from unit and water bucket. Do not block air intake or exhaust. Do not operate in explosive atmospheres. Disconnect power before servicing.

Regulatory Information

This dehumidifier complies with FCC Part 15 Class B limits. Manufacturer: Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629. This product contains refrigerant; dispose of according to local regulations.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not startNo power, full bucket, timer setCheck outlet; empty bucket; check timer settings.
Reduced moisture removalDirty filter, low temperatureClean filter; ensure room temp above 41°F.
Water leakageBucket not seated, unit not levelReinsert bucket; level the unit.
Loud noiseLoose parts, vibrationEnsure unit is on solid surface; check for obstructions.
Display not workingPower issueUnplug for 1 minute, then reconnect.
Bucket full light on (empty bucket)Float stuckRemove bucket, check float moves freely, clean if necessary.

Reset: Unplug for 10 minutes to reset electronic controls.

Service: 1-800-263-2629; www.danby.com

Danby DDR060BDWDB Dehumidifier Manual © - All Rights Reserved 2025