The Danby DDR060BECWDB is a 60-pint energy-efficient dehumidifier designed for residential use. It features automatic humidity control, a continuous drain option, a full tank alert with auto-shutoff, a washable air filter, a digital display, a 24-hour timer, and quiet operation. Ideal for basements, living areas, and other spaces up to 3000 sq. ft. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Storage & Winterization 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Digital Control Panel, Water Tank, Continuous Drain Hose Port, Washable Air Filter, Casters for Mobility, Handle for Transport.

FeatureDescription
Digital Control PanelFor setting humidity level, timer, and viewing status
60-Pint CapacityRemoves up to 60 pints per day (at 80°F, 60% RH)
Automatic Humidity ControlMaintains set humidity level (30%-90% RH)
Continuous Drain OptionGravity drain port for hose connection
Full Tank Alert & Auto-ShutoffStops operation and lights indicator when tank is full
Washable Air FilterCaptures airborne particles; can be cleaned
24-Hour TimerProgram on/off cycles
Quiet OperationLow noise design for living spaces
Casters & HandleFor easy mobility and placement
Energy EfficientENERGY STAR® certified

Installation & Placement

Unpack and inspect contents. Place on a level, stable surface.

  1. Clearance: Ensure at least 12 inches of clearance on all sides for proper airflow.
  2. Positioning: Place in the center of the room or area with high humidity. Avoid corners.
  3. Power Source: Plug directly into a grounded 115V AC, 60Hz outlet. Do not use an extension cord.
  4. Drain Setup: For continuous drainage, attach hose to drain port and route to floor drain or sink.

WARNING! Do not place near heat sources or in direct sunlight. Ensure the unit is upright for at least 24 hours before first use if transported on its side.

First-Time Setup

Plug in the dehumidifier; the control panel will illuminate.

  1. Initial Run: The unit will start in Auto mode at 50% RH default setting.
  2. Set Desired Humidity: Press the HUMIDITY button to set your target level (30%-90%).
  3. Timer Setup (Optional): Use the TIMER button to program automatic start/stop times.
  4. Check Drainage: Ensure water tank is properly seated or continuous drain hose is securely attached.

CAUTION! Handle the water tank with care. Do not operate without the air filter installed.

Specifications

Controls and Settings

Access all functions via the Digital Control Panel on top of the unit.

Control Panel: POWER Button, HUMIDITY Up/Down Buttons, FAN Speed (High/Low), TIMER Button, FILTER Alert Indicator, FULL TANK Indicator.

Modes: AUTO (maintains set humidity), CONTINUOUS (runs constantly). Fan Speed: Adjust between High (faster dehumidification) and Low (quieter operation). Timer: Set from 1 to 24 hours for automatic shutdown or startup. Alerts: FILTER light indicates when to clean the air filter; FULL TANK light illuminates when bucket needs emptying.

Operation Modes

Auto Mode: Unit cycles on/off to maintain the set humidity level. Continuous Mode: Runs constantly until turned off or tank is full.

  1. Press POWER to turn on.
  2. Select mode: Press MODE to cycle between Auto and Continuous.
  3. In Auto Mode: Set target humidity with HUMIDITY buttons.
  4. Adjust Fan: Press FAN to select High or Low speed.
  5. For Timer: Press TIMER, then use arrows to set hours, press TIMER again to confirm.

Tip: Use Continuous mode for rapid moisture removal after flooding or in very damp conditions.

Maintenance & Cleaning

Unplug the unit before any maintenance.

  1. Empty Water Tank: Remove tank, pour out water, clean with mild detergent, rinse, and dry before reinserting.
  2. Clean Air Filter: Remove filter every 2 weeks or when FILTER light is on. Wash with warm, soapy water, rinse, and air dry completely.
  3. Exterior Cleaning: Wipe cabinet with a soft, damp cloth. Do not use abrasive cleaners.
  4. Condenser Coil: Vacuum the rear coil annually to remove dust.
  5. End-of-Season: Follow storage procedures if not using for extended periods.

WARNING! Never immerse the unit in water. Do not operate without the filter.

Storage & Winterization

If storing the dehumidifier for more than a few weeks:

  1. Unplug the unit.
  2. Empty and thoroughly dry the water tank.
  3. Clean the air filter and let it dry.
  4. Run the unit in Fan Only mode (if available) for 30 minutes to dry internal components.
  5. Coil the power cord neatly.
  6. Store in a cool, dry place, covered to prevent dust accumulation.

CAUTION! Store in an area where temperatures will not drop below freezing.

Regulatory Information

This appliance complies with Part 15 of the FCC Rules. Operation is subject to the condition that it does not cause harmful interference. This product is ETL listed to UL standard 474. Copyright © Danby Products Inc. For support, visit www.danby.com or contact customer service at 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not startNo power / Full tankEnsure plug is secure; outlet has power; empty water tank.
Little or no water collectionLow humidity / Cold roomRoom humidity may already be low; unit runs less. Not effective below 65°F.
Unit runs but stops quicklySet humidity too highLower the target humidity setting on control panel.
FILTER light is onDirty air filterClean the washable air filter as per instructions.
Loud or unusual noiseUneven surface / Loose partsPlace unit on level floor; ensure water tank and filter are properly seated.
Water leakageTank not seated / Drain hose issueRemove and reinsert tank; check drain hose for kinks or blockages.

Reset: Unplug for 60 seconds, then plug back in.