Danby DDR060BFCWDB Dehumidifier Manual

The Danby DDR060BFCWDB is a 60-pint capacity dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage option, digital display with humidity readout, 24-hour timer, auto-restart after power interruption, washable air filter, and energy-efficient operation. Suitable for areas up to 3000 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Modes 7. Maintenance & Cleaning 8. Storage & Winterization 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Digital control panel, Water tank with full indicator, Continuous drainage port, Washable air filter, Casters for mobility, Handle for transport.

FeatureDescription
Digital DisplayShows current humidity level and settings
Automatic Humidity ControlMaintains set humidity level (30%-80% RH)
Continuous DrainageOption for hose connection (5/8" inner diameter)
24-Hour TimerProgram on/off cycles
Auto-RestartResumes previous settings after power outage
Washable Air FilterRemovable for cleaning
Full Tank AlertIndicator light and auto-shutoff when tank is full
Turbo ModeMaximum dehumidification speed
Energy Saver ModeOptimizes energy consumption
Portable DesignBuilt-in handle and casters for easy movement

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Clear area: Ensure at least 12 inches clearance on all sides for proper airflow.
  2. Position near drain: If using continuous drainage, place within 5 feet of floor drain.
  3. Check power: Use dedicated 115V/60Hz outlet; avoid extension cords.
  4. Install drainage hose: Attach 5/8" ID hose to drainage port for continuous operation.

WARNING! Do not place near heat sources or in direct sunlight. Ensure room temperature is between 41°F and 95°F for optimal operation.

First-Time Setup

Plug into power outlet; unit will beep and display will illuminate.

  1. Set humidity level: Press HUMIDITY button to select desired level (40-50% recommended).
  2. Choose mode: Select NORMAL, TURBO, or ENERGY SAVER mode based on needs.
  3. Set timer: Press TIMER to program automatic start/stop times if desired.
  4. Check filter: Ensure air filter is clean and properly installed.

CAUTION! Allow unit to stand upright for 24 hours if transported on its side before operating.

Specifications

Controls and Settings

Access controls via digital panel or included remote control. Front Panel: POWER, MODE, HUMIDITY, TIMER, FAN SPEED, FILTER RESET.

Remote: POWER, MODE, HUMIDITY, TIMER, FAN SPEED, LIGHTS.

Humidity: Set desired level (30%-80%). Mode: NORMAL, TURBO, ENERGY SAVER, CONTINUOUS. Timer: 24-hour programmable on/off. Fan Speed: HIGH or LOW. Filter Alert: Indicator light when filter needs cleaning. Display: Brightness adjustable or can be turned off.

Operating Modes

NORMAL: Standard dehumidification with automatic cycling. TURBO: Maximum moisture removal for high humidity conditions. ENERGY SAVER: Compressor runs only when needed to save energy. CONTINUOUS: Runs continuously regardless of humidity level (with drainage hose).

  1. Select mode based on humidity level and energy preferences.
  2. Monitor water tank: Empty when FULL indicator lights or use continuous drainage.
  3. Adjust fan speed: Higher speed increases air circulation but may be louder.

Tip: For best results, keep doors and windows closed while dehumidifier is running.

Maintenance & Cleaning

Unplug unit before performing any maintenance.

  1. Clean air filter: Remove and wash with mild detergent every 2 weeks or as needed.
  2. Empty water tank: Regularly empty and clean tank to prevent mold/mildew.
  3. Clean exterior: Use soft, damp cloth; do not use abrasive cleaners.
  4. Check drainage hose: Ensure continuous drainage hose is clear of obstructions.
  5. Reset filter indicator: Press FILTER RESET after cleaning filter.

WARNING! Never operate without air filter. Do not immerse unit in water.

Storage & Winterization

If not using for extended period, prepare for storage:

  1. Unplug unit and empty water tank completely.
  2. Clean air filter and let dry completely.
  3. Run unit in FAN ONLY mode for 24 hours to dry internal components.
  4. Coil power cord neatly and store in original box if available.
  5. Store in dry, cool place away from direct sunlight.

CAUTION! Do not store with water in tank. Protect from freezing temperatures.

Regulatory Information

UL Listed: Certified for safety standards. Energy Star: Meets energy efficiency guidelines. EPA Refrigerant Compliance: Uses R410A refrigerant. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onPower issueCheck power outlet; ensure plug is secure; check circuit breaker.
Not removing moistureTemperature/RHEnsure room temperature 41°F-95°F; check humidity setting; clean filter.
Water leakingTank/drainageEnsure tank properly seated; check drainage hose connection; empty full tank.
Loud noisePlacement/filterEnsure unit is level; check for loose parts; clean air filter.
Display not workingPower/displayCheck power connection; press LIGHTS button to adjust display brightness.
Ice on coilsLow temperatureTurn unit off and let ice melt; move to warmer area; check room temperature.

Reset: Unplug for 5 minutes, then restart.

Service: 1-800-263-2629; www.danby.com