Danby DDR060BMPWDB Dehumidifier Manual

The Danby DDR060BMPWDB is a 60-pint dehumidifier designed for medium to large rooms, featuring an auto-defrost function for low-temperature operation, continuous drainage option, digital humidity display, 24-hour timer, washable filter, and energy-efficient operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance 8. Drainage Options 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, removable water bucket, continuous drain hose connection, washable air filter, casters for mobility, and auto-restart function.

FeatureDescription
Digital Control PanelLED display for humidity level and settings
Removable Water Bucket60-pint capacity with full-bucket alert and auto-shutoff
Continuous Drain Hose ConnectionFor unattended operation with gravity drainage
Washable Air FilterCaptures dust and particles; improves air quality
Auto-Defrost FunctionAllows operation in temperatures as low as 41°F (5°C)
24-Hour TimerProgram start/stop times for energy savings
Humidity ControlAdjustable from 35% to 85% relative humidity
Fan Speed SettingsHigh and Low settings for customized operation
CastersFour wheels for easy mobility
Auto-RestartResumes previous settings after power interruption

Installation

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place unit at least 12 inches from walls and furniture for proper airflow.
  2. Install Casters: Attach all four wheels to base if not pre-installed.
  3. Install Drain Hose (optional): Connect hose to drain port for continuous drainage.
  4. Plug into dedicated 115V AC power outlet.

WARNING! Do not use extension cords. Ensure unit is upright for at least 24 hours before first use if transported on its side.

First-Time Setup

Power on dehumidifier; follow control panel prompts.

  1. Set Desired Humidity: Press HUMIDITY button to select target level (35%-85%).
  2. Select Fan Speed: Press FAN button to choose High or Low setting.
  3. Set Timer (optional): Press TIMER to program on/off schedule.
  4. Check Water Bucket: Ensure bucket is properly seated and empty.
  5. For Continuous Drainage: Connect hose and ensure downward slope.

CAUTION! Do not operate in temperatures below 41°F (5°C) without auto-defrost enabled.

Specifications

Controls and Settings

Access all functions via digital control panel. Front Panel: POWER, HUMIDITY, FAN, TIMER, MODE.

Display Indicators: Current humidity, target humidity, timer settings, filter alert, full bucket alert, defrost mode.

Humidity Control: Adjust target humidity in 5% increments. Fan Speed: High for maximum moisture removal, Low for quiet operation. Timer: Set 1-24 hours for automatic start/stop. Mode: Continuous mode (runs until turned off) or Auto mode (maintains set humidity).

Operation Modes

Auto Mode: Unit runs until target humidity is reached, then cycles on/off to maintain level. Continuous Mode: Runs continuously regardless of humidity level. Timer Mode: Programmed operation for specific periods.

  1. Press POWER to turn unit on.
  2. Press MODE to select Auto or Continuous operation.
  3. Press HUMIDITY to set desired humidity level.
  4. Press FAN to select High or Low speed.
  5. Press TIMER to set automatic shutoff or startup.

Tip: Use Auto mode for energy efficiency; Continuous mode for maximum moisture removal.

Maintenance

Regular maintenance ensures optimal performance and longevity.

  1. Empty Water Bucket: When full bucket indicator lights, turn off unit and empty bucket.
  2. Clean Air Filter: Remove and wash filter every 2 weeks under running water.
  3. Clean Exterior: Wipe with damp cloth; do not use harsh chemicals.
  4. Check Drain Hose: Ensure continuous drain hose is clear of obstructions.
  5. Off-Season Storage: Empty all water, clean unit, and store in upright position.

WARNING! Always unplug unit before performing any maintenance.

Drainage Options

Bucket Drainage: Standard method; empty when full bucket indicator lights. Continuous Drainage: Connect 5/8" ID hose to drain port for unattended operation.

Continuous Drain Setup:

  1. Turn off and unplug unit.
  2. Remove drain plug from back of unit.
  3. Connect hose (not included) to drain port.
  4. Route hose to floor drain or suitable outlet.
  5. Ensure hose has constant downward slope.

Care & Cleaning

Unplug before cleaning. Clean exterior with soft, damp cloth. Wash air filter with mild detergent and water; air dry completely before reinstalling.

CAUTION! Do not immerse unit in water. Do not use gasoline, thinners, or abrasive cleaners.

Regulatory Information

UL Listed; meets safety standards. EPA Energy Star certified. This product contains refrigerant that must be recovered by certified technicians. For support, visit www.danby.com or contact 1-800-263-2629. Copyright © Danby Products Inc. All rights reserved.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onPower issueCheck power cord connection; ensure outlet has power; check circuit breaker.
Low moisture removalRoom conditions/filterEnsure room temperature above 41°F; clean air filter; check for obstructions.
Water leakingBucket/drain issuesEnsure bucket properly seated; check drain hose connection; empty full bucket.
Loud noiseVibration/obstructionPlace on level surface; check for objects touching unit; ensure internal components secure.
Ice on coilsLow temperatureAuto-defrost should activate; if persistent, move to warmer area or turn off temporarily.
Error codes on displaySystem faultsConsult manual error code chart; if persistent, contact service center.

Reset: Unplug for 5 minutes, then restart.

Service: 1-800-263-2629; www.danby.com