Danby DDR060EACWDB Dehumidifier Manual

The Danby DDR060EACWDB is a 60-pint energy-efficient dehumidifier designed for medium to large rooms, featuring an auto-defrost function for low-temperature operation, continuous drain option, digital humidity display, 24-hour timer, washable air filter, and quiet operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Instructions 7. Maintenance & Cleaning 8. Storage 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Digital control panel, Removable water bucket with full-bucket alert, Continuous drain hose connection, Washable air filter, Auto-restart function, and Energy Star certified.

FeatureDescription
Digital Humidity DisplayShows current room humidity and set target
60-Pint CapacityRemoves up to 60 pints per day (AHAM certified)
Auto-DefrostAllows operation in temperatures as low as 41°F (5°C)
Continuous Drain OptionGarden hose connection for unattended operation
24-Hour TimerProgram start/stop times for energy savings
Washable Air FilterCaptures airborne particles; can be cleaned and reused
Full-Bucket AlertIndicator light and auto-shutoff when bucket is full
Auto-RestartResumes previous settings after a power interruption
Quiet OperationDesigned for low noise in living spaces
Energy Star CertifiedMeets energy efficiency guidelines

Installation

Unpack and inspect contents. Place on a level, stable floor.

  1. Positioning: Place unit at least 6 inches from walls and furniture for proper airflow.
  2. Bucket Installation: Ensure water bucket is correctly seated and locked in place.
  3. Continuous Drain (Optional): Attach standard garden hose to drain port; route hose to floor drain or sink.
  4. Power Connection: Plug into a dedicated 115V AC, 60Hz outlet. Do not use an extension cord.

WARNING! Do not operate in temperatures below 41°F (5°C) unless using auto-defrost mode. Ensure unit is upright for at least 24 hours before first use if tilted during transport.

First-Time Setup

Plug in the unit; the control panel will illuminate.

  1. Set Target Humidity: Press the HUMIDITY button to set desired level (35% - 85%).
  2. Select Fan Speed: Choose LOW for quiet operation or HIGH for maximum moisture removal.
  3. Timer Setting (Optional): Use TIMER button to program on/off cycles.
  4. Continuous Mode: Press CONTINUOUS button for maximum dehumidification regardless of humidity.

CAUTION! Do not block air intake or exhaust grilles. Keep children and pets away from the unit.

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY (+/-), FAN SPEED (LOW/HIGH), TIMER, CONTINUOUS, FILTER ALERT RESET.

Display Indicators: Current humidity, Set humidity, Fan speed, Timer, Full bucket, Filter clean, Defrost mode.

Humidity Control: Adjust between 35% and 85% in 5% increments. Fan Speed: LOW for quiet operation, HIGH for faster dehumidification. Timer: Set 1-24 hours for automatic start or stop. Continuous Mode: Runs continuously until manually turned off. Filter Alert: Light illuminates when air filter needs cleaning (after 250 hours of operation).

Operating Instructions

For optimal performance, close windows and doors in the room.

  1. Power On: Press POWER button; unit will begin operating.
  2. Monitor Humidity: Display shows current room humidity; adjust target as needed.
  3. Empty Water Bucket: When FULL indicator lights, power off, remove bucket, empty, and replace.
  4. Continuous Drain: Connect hose to drain port; unit will drain automatically without bucket emptying.
  5. Defrost Cycle: In low temperatures, unit may enter auto-defrost; compressor stops temporarily until coils thaw.

Tip: For maximum efficiency, operate in the coolest part of the room and keep doors to other rooms closed.

Maintenance & Cleaning

Unplug unit before any maintenance.

  1. Air Filter: Clean every 2-4 weeks or when FILTER light comes on. Rinse under warm water, dry completely before reinstalling.
  2. Water Bucket: Empty and clean monthly with mild detergent to prevent mold/mildew.
  3. Exterior: Wipe with a soft, damp cloth. Do not use abrasive cleaners.
  4. Grilles and Vents: Use vacuum attachment to remove dust buildup.
  5. End-of-Season: Clean thoroughly before storage (see Storage section).

WARNING! Never immerse unit in water. Do not use chemicals or solvents on plastic parts.

Storage

If not using for extended periods, prepare unit for storage.

  1. Unplug the unit and empty water bucket completely.
  2. Clean air filter and all accessible surfaces.
  3. Run unit in FAN ONLY mode for 24 hours in a warm room to dry internal components.
  4. Coil drain hose (if attached) and store with unit.
  5. Store in a cool, dry place, protected from dust.

CAUTION! Store unit upright. Do not place heavy objects on top.

Regulatory Information

This dehumidifier complies with FCC Part 15 Subpart B for unintentional radiators. This device complies with Industry Canada license-exempt RSS standard(s). Copyright © Danby Products Inc. All rights reserved. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not startNo power/bucket fullEnsure plug is secure; empty water bucket; check circuit breaker.
Reduced moisture removalDirty filter/extreme conditionsClean air filter; ensure room temp is between 41°F-95°F; close windows.
Unit runs but no water collectionLow humidity/defrost cycleRoom may already be dry; wait for humidity to rise. In cold temps, defrost cycle may pause collection.
Water leakageBucket not seated/hose connectionEnsure bucket is properly locked; check drain hose for kinks or blockages.
Loud or unusual noiseLoose parts/foreign objectsEnsure unit is on level surface; check for objects near fan; contact service if noise persists.
FILTER light onAir filter needs cleaningClean filter as per instructions; press and hold FILTER RESET for 3 seconds.

Reset: Unplug unit for 5 minutes, then restart.

Service: 1-800-263-2629; www.danby.com