Danby DDR070BBWDB Dehumidifier Manual

The Danby DDR070BBWDB is a 70-pint dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage option, digital display with humidity readout, 24-hour timer, washable air filter, auto-defrost function, and energy-efficient operation. Ideal for medium to large rooms up to 4500 sq ft. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance 8. Drainage Options 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, 70-pint water tank, Continuous drain hose connection, Washable air filter, Casters for mobility, Auto-restart function.

FeatureDescription
Digital Control PanelLED display with humidity readout and control buttons
70-Pint CapacityRemoves up to 70 pints of moisture per day (at 80°F, 60% RH)
Continuous DrainageOption for hose connection to drain water automatically
Washable Air FilterRemovable filter for easy cleaning
Auto-DefrostPrevents coil freezing in low temperatures
24-Hour TimerProgrammable on/off cycles
Auto Humidity ControlMaintains set humidity level (30%-80% RH)
Full Tank AlertIndicator light and auto shut-off when tank is full
CastersFour wheels for easy mobility
Auto-RestartResumes previous settings after power interruption

Installation

Unpack and inspect contents. Place on level, stable surface.

  1. Remove packaging materials and tape from unit.
  2. Position dehumidifier: Ensure at least 12 inches clearance from walls and furniture.
  3. Install casters: Attach four wheels to bottom of unit (if not pre-installed).
  4. Check filter: Ensure washable air filter is properly seated.
  5. Plug into dedicated 115V AC power outlet.

WARNING! Do not use extension cords. Ensure proper ventilation around unit.

First-Time Setup

Power on dehumidifier; configure initial settings.

  1. Set desired humidity: Press HUMIDITY button to select 45-50% RH (recommended).
  2. Select fan speed: Choose HIGH or LOW setting based on room size.
  3. Set timer (optional): Program 24-hour on/off schedule if needed.
  4. Check drainage: For continuous drainage, attach hose to drain port.
  5. Allow 24 hours for optimal performance in new environment.

CAUTION! Do not operate in temperatures below 41°F (5°C).

Specifications

Controls and Settings

Digital Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, FILTER RESET.

Display Indicators: Current humidity, Set humidity, Timer settings, Filter alert, Full tank alert, Defrost mode.

Humidity Control: Adjust between 30%-80% RH in 5% increments. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: Program on/off cycles in 1-hour increments up to 24 hours. Auto Mode: Unit automatically adjusts operation to maintain set humidity. Continuous Mode: Runs continuously regardless of humidity level.

Operation Modes

Auto Mode: Recommended for most applications. Continuous Mode: For maximum moisture removal.

  1. Press POWER button to turn unit on.
  2. Select mode: Press MODE button to choose AUTO or CONTINUOUS.
  3. Set humidity: In AUTO mode, use HUMIDITY buttons to set desired level.
  4. Select fan speed: Press FAN button for HIGH or LOW setting.
  5. Monitor: Display shows current room humidity and operating status.

Tip: For energy savings, set humidity to 50% in summer, 40% in winter.

Maintenance

Regular maintenance ensures optimal performance and longevity.

  1. Clean air filter: Remove and wash every 2 weeks or as needed.
  2. Empty water tank: When full tank light illuminates, turn off unit and empty tank.
  3. Clean exterior: Wipe with damp cloth; never use harsh chemicals.
  4. Check drain hose: Ensure continuous drain hose is clear of obstructions.
  5. Off-season storage: Empty tank, clean unit, and store in dry location.

WARNING! Always unplug unit before performing any maintenance.

Drainage Options

Two drainage methods: Manual (bucket) or Continuous (hose).

Manual Drainage: Unit automatically shuts off when tank is full. Empty tank by lifting from unit and pouring out water.

Continuous Drainage: Attach 5/8" ID hose to drain port at back of unit. Ensure hose runs downward to floor drain or sink. Unit will drain automatically without need to empty tank.

Care & Cleaning

Unplug before cleaning. Clean exterior with soft, damp cloth. Wash air filter with mild detergent and warm water; air dry completely before reinstalling.

CAUTION! Do not immerse unit in water. Do not use gasoline, thinners, or abrasive cleaners.

Regulatory Information

UL Listed. CSA Certified. Energy Star qualified. This product contains refrigerant that must be recovered by certified technician. For disposal, consult local regulations. Manufactured for Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not operatingNo powerCheck power cord connection; ensure outlet has power; check circuit breaker.
Reduced moisture removalDirty filter/extreme conditionsClean air filter; ensure room temperature above 41°F; check for obstructions.
Water leakingImproper hose connection/full tankCheck drain hose connection; empty water tank; ensure unit is level.
Loud noiseLoose parts/obstructionsEnsure unit is on level surface; check for objects near fan; tighten any loose parts.
Display not workingPower issueUnplug for 10 minutes, then reconnect; check power source.
Frost on coilsLow temperatureAuto-defrost should activate; move to warmer location if below 41°F.

Reset: Unplug unit for 10 minutes to reset control board.

Service: 1-800-263-2629; www.danby.com

Danby DDR070BBWDB Dehumidifier Manual © - All Rights Reserved 2025