The Danby DDR070BDWDB is a 70-pint dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage option, washable air filter, auto-defrost, digital controls with LED display, 24-hour timer, and energy-efficient operation. Ideal for basements, living areas, and other spaces up to 4500 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Digital control panel, 70-pint water tank, washable air filter, continuous drainage hose, casters for mobility, and auto-restart function.
| Feature | Description |
|---|---|
| Capacity | 70 pints per day (at 60°F, 90% RH) |
| Digital Controls | LED display with humidity readout and settings |
| Auto Humidity Control | Set desired humidity level (35%-85%) |
| Continuous Drainage | Garden hose connection for continuous operation |
| Washable Air Filter | Removable and reusable filter |
| Auto Defrost | Prevents coil freezing in low temperatures |
| 24-Hour Timer | Program on/off cycles |
| Full Tank Alert | LED indicator and auto shut-off when tank is full |
| Power Cord Storage | Built-in cord wrap |
| Casters | Four wheels for easy mobility |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not use extension cords. Ensure proper ventilation around unit.
Power on dehumidifier; follow control panel prompts.
CAUTION! Allow unit to sit upright for 24 hours if transported on its side.
Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, FILTER RESET.
Display Indicators: Current humidity, set humidity, fan speed, timer, full tank, filter clean, defrost.
Humidity Control: Set between 35%-85% (increments of 5%). Fan Speed: HIGH for maximum dehumidification, LOW for quiet operation. Timer: Program on/off cycles in 1-hour increments. Filter Reset: Press after cleaning filter. Auto Restart: Unit resumes previous settings after power interruption.
Two drainage methods: Manual (bucket) or Continuous (hose).
Tip: For continuous operation, use hose drainage to avoid frequent emptying.
Regular maintenance ensures optimal performance.
WARNING! Unplug unit before any maintenance. Do not immerse in water.
Maximize efficiency and reduce energy consumption.
Proper storage extends unit lifespan.
CAUTION! Store in temperature-controlled area. Do not place heavy items on top.
UL Listed. CSA Certified. Energy Star qualified. This product contains refrigerant that must be recovered by certified technicians. For technical support, visit www.danby.com or contact 1-800-263-2629. Copyright © Danby Products Inc. All rights reserved.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | Power issue/full tank | Check power connection; empty water tank; reset circuit breaker. |
| Poor dehumidification | Dirty filter/room temp | Clean air filter; ensure room temperature above 41°F. |
| Water leakage | Improper hose connection | Check hose for kinks; ensure proper connection to drain port. |
| Loud noise | Loose parts/uneven surface | Ensure unit is level; check for loose panels or foreign objects. |
| Frost on coils | Low temperature | Auto-defrost should activate; move to warmer area if persistent. |
| Error codes on display | System fault | Consult manual error code chart; power cycle unit. |
Reset: Unplug for 5 minutes, then restart.
Service: 1-800-263-2629; www.danby.com