The Danby DDR070EAPWDB is a 70-pint dehumidifier designed for residential use, featuring electronic controls, a continuous drain option, auto-restart, auto-defrost, a 24-hour timer, washable air filter, and a full tank alert with auto shut-off. It operates on 115V/60Hz and is ideal for medium to large rooms. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Electronic control panel, removable water bucket, continuous drain hose connection, washable air filter, casters for mobility, and humidity sensor.
| Feature | Description |
|---|---|
| Electronic Controls | Digital display with touchpad for setting target humidity and timer |
| 70-Pint Capacity | Removes up to 70 pints of moisture per day (at 80°F, 60% RH) |
| Continuous Drain Option | Garden hose connection for unattended operation |
| Auto-Restart | Resumes previous settings after a power interruption |
| Auto-Defrost | Prevents coil freezing in low temperatures |
| 24-Hour Timer | Program on/off cycles for energy savings |
| Full Tank Alert & Auto Shut-Off | Alerts when bucket is full and stops operation |
| Washable Air Filter | Captures airborne particles; can be cleaned |
| Humidity Sensor | Monitors room humidity and adjusts operation |
| Casters | Four wheels for easy mobility |
Unpack and inspect contents. Place on a level, stable surface away from obstructions.
WARNING! Do not place in tight enclosures or near heat sources. Ensure the unit is upright before operating.
Plug in the dehumidifier; the control panel will illuminate.
CAUTION! Allow the unit to sit upright for 24 hours if it was tilted during transport.
Access all functions via the electronic control panel on top of the unit.
Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, FILTER ALERT RESET.
Display Icons: Power, Bucket Full, Defrost, Filter Clean, Target Humidity, Fan Speed, Timer Set.
Humidity Control: Set target from 35% to 80% in 5% increments. The unit will run until the room reaches this level, then cycle on/off to maintain it.
Fan Speed: HIGH for maximum moisture removal, LOW for quieter operation.
Timer: Set delay start or delay stop from 1 to 24 hours.
Filter Alert: LED illuminates after 250 hours of operation as a reminder to clean the air filter.
Normal Dehumidification: Unit runs continuously until target humidity is met, then cycles.
Continuous Mode: Set humidity to "CONT" (Continuous). The unit will run non-stop regardless of room humidity, ideal for very damp conditions or when using the continuous drain.
Auto-Defrost: Activates automatically when frost is detected on the coils. The compressor stops and the fan runs until coils are clear.
Bucket Mode: When the internal bucket is full, the unit stops and the "Bucket Full" icon lights up. Empty the bucket and reinsert to resume.
Drain Hose Mode: Connect a standard garden hose (not included) to the drain port for continuous water removal. The bucket full alert is disabled.
Unplug the unit before any maintenance.
CAUTION! Never operate without the air filter. Do not immerse any part of the unit in water.
If not using for an extended period (e.g., winter):
Tip: Cover the unit to prevent dust accumulation during storage.
This dehumidifier complies with relevant U.S. safety and performance standards. The refrigerant system is sealed; only qualified personnel should service it. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.
Energy Guide: Estimated yearly energy cost based on 8.3¢ per kWh. Actual cost may vary.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit does not start | No power / Bucket full / Bucket not seated | Check plug and outlet; empty and reinsert bucket; ensure bucket is clicked into place. |
| Little or no water collection | Low humidity / Cold room / Dirty filter / Incorrect settings | Check room humidity; ensure room temp >41°F; clean filter; set lower target humidity or use CONTINUOUS mode. |
| Unit runs but stops frequently | Auto-defrost cycle / Target humidity reached | This is normal in low temps; wait for cycle to end. If humidity is at target, unit will cycle. |
| Loud or unusual noise | Unit not level / Loose parts / Airflow obstruction | Place on level floor; check for loose panels; ensure grilles are clear. |
| Error Code "E1" or "E2" | Sensor fault | Unplug for 5 minutes, then restart. If persists, contact service. |
| Water leakage | Bucket misaligned / Drain hose not connected properly | Remove and reinsert bucket; check hose connection and path for kinks. |
Reset: Unplug the unit for 5 minutes to reset the electronic control system.
Service: 1-800-263-2629; www.danby.com