Danby DDR070EAPWDB Dehumidifier Manual

The Danby DDR070EAPWDB is a 70-pint dehumidifier designed for residential use, featuring electronic controls, a continuous drain option, auto-restart, auto-defrost, a 24-hour timer, washable air filter, and a full tank alert with auto shut-off. It operates on 115V/60Hz and is ideal for medium to large rooms. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Storage & Winterization 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Electronic control panel, removable water bucket, continuous drain hose connection, washable air filter, casters for mobility, and humidity sensor.

FeatureDescription
Electronic ControlsDigital display with touchpad for setting target humidity and timer
70-Pint CapacityRemoves up to 70 pints of moisture per day (at 80°F, 60% RH)
Continuous Drain OptionGarden hose connection for unattended operation
Auto-RestartResumes previous settings after a power interruption
Auto-DefrostPrevents coil freezing in low temperatures
24-Hour TimerProgram on/off cycles for energy savings
Full Tank Alert & Auto Shut-OffAlerts when bucket is full and stops operation
Washable Air FilterCaptures airborne particles; can be cleaned
Humidity SensorMonitors room humidity and adjusts operation
CastersFour wheels for easy mobility

Installation & Placement

Unpack and inspect contents. Place on a level, stable surface away from obstructions.

  1. Choose Location: Place in center of room or area with high humidity, at least 8 inches from walls and furniture for proper airflow.
  2. Check Airflow: Ensure air inlet and outlet grilles are unobstructed.
  3. Set Up Drainage: For bucket operation, ensure bucket is correctly seated. For continuous drain, attach garden hose to drain port and route to floor drain or sink.
  4. Plug into Power: Use a dedicated 115V outlet. Do not use an extension cord.

WARNING! Do not place in tight enclosures or near heat sources. Ensure the unit is upright before operating.

First-Time Setup

Plug in the dehumidifier; the control panel will illuminate.

  1. Set Target Humidity: Press the HUMIDITY button to select desired level (35%-80%). The unit will cycle to maintain this setting.
  2. Select Fan Speed: Press FAN button to choose HIGH or LOW speed.
  3. Set Timer (Optional): Press TIMER to program automatic start/stop times.
  4. Begin Operation: Press POWER to start. The compressor may take 3 minutes to start after initial power-up or after a cycle.

CAUTION! Allow the unit to sit upright for 24 hours if it was tilted during transport.

Specifications

Controls and Settings

Access all functions via the electronic control panel on top of the unit.

Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, FILTER ALERT RESET.

Display Icons: Power, Bucket Full, Defrost, Filter Clean, Target Humidity, Fan Speed, Timer Set.

Humidity Control: Set target from 35% to 80% in 5% increments. The unit will run until the room reaches this level, then cycle on/off to maintain it.

Fan Speed: HIGH for maximum moisture removal, LOW for quieter operation.

Timer: Set delay start or delay stop from 1 to 24 hours.

Filter Alert: LED illuminates after 250 hours of operation as a reminder to clean the air filter.

Operation Modes

Normal Dehumidification: Unit runs continuously until target humidity is met, then cycles.

Continuous Mode: Set humidity to "CONT" (Continuous). The unit will run non-stop regardless of room humidity, ideal for very damp conditions or when using the continuous drain.

Auto-Defrost: Activates automatically when frost is detected on the coils. The compressor stops and the fan runs until coils are clear.

Bucket Mode: When the internal bucket is full, the unit stops and the "Bucket Full" icon lights up. Empty the bucket and reinsert to resume.

Drain Hose Mode: Connect a standard garden hose (not included) to the drain port for continuous water removal. The bucket full alert is disabled.

Maintenance & Cleaning

Unplug the unit before any maintenance.

  1. Empty Water Bucket: Remove, empty, and replace securely. Clean with mild detergent monthly.
  2. Clean Air Filter: Remove filter every 2 weeks or when FILTER light is on. Wash with warm water and mild soap, let dry completely before reinstalling. Press FILTER RESET button.
  3. Clean Exterior: Wipe cabinet with a soft, damp cloth. Do not use abrasive cleaners.
  4. Clean Coils and Grilles: Use a vacuum cleaner brush attachment to remove dust from the rear coil and air grilles annually.

CAUTION! Never operate without the air filter. Do not immerse any part of the unit in water.

Storage & Winterization

If not using for an extended period (e.g., winter):

  1. Unplug the unit.
  2. Empty and clean the water bucket. Let it dry.
  3. Clean the air filter and let it dry.
  4. Run the unit in FAN ONLY mode for a few hours to dry the interior.
  5. Coil the power cord neatly.
  6. Store upright in a dry, covered location.

Tip: Cover the unit to prevent dust accumulation during storage.

Regulatory Information

This dehumidifier complies with relevant U.S. safety and performance standards. The refrigerant system is sealed; only qualified personnel should service it. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Energy Guide: Estimated yearly energy cost based on 8.3¢ per kWh. Actual cost may vary.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not startNo power / Bucket full / Bucket not seatedCheck plug and outlet; empty and reinsert bucket; ensure bucket is clicked into place.
Little or no water collectionLow humidity / Cold room / Dirty filter / Incorrect settingsCheck room humidity; ensure room temp >41°F; clean filter; set lower target humidity or use CONTINUOUS mode.
Unit runs but stops frequentlyAuto-defrost cycle / Target humidity reachedThis is normal in low temps; wait for cycle to end. If humidity is at target, unit will cycle.
Loud or unusual noiseUnit not level / Loose parts / Airflow obstructionPlace on level floor; check for loose panels; ensure grilles are clear.
Error Code "E1" or "E2"Sensor faultUnplug for 5 minutes, then restart. If persists, contact service.
Water leakageBucket misaligned / Drain hose not connected properlyRemove and reinsert bucket; check hose connection and path for kinks.

Reset: Unplug the unit for 5 minutes to reset the electronic control system.

Service: 1-800-263-2629; www.danby.com