Danby DDR60A2CP Dehumidifier Manual

The Danby DDR60A2CP is a 60-pint capacity dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage option, 24-hour timer, washable air filter, and digital controls with LED display. It operates on 115V/60Hz power and is ideal for medium to large rooms up to 3000 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Modes 7. Maintenance & Cleaning 8. Storage & Winterization 9. Safety Information 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, 60-pint water tank, washable filter, continuous drain hose connection, casters for mobility, and auto-defrost function.

FeatureDescription
Capacity60 pints per day (at 80°F, 60% RH)
Control PanelDigital LED display with touch controls
Humidity ControlAuto humidity set from 35% to 85%
Timer24-hour programmable on/off timer
FilterWashable air filter
Drain OptionsBuilt-in tank or continuous drain hose
Auto RestartResumes previous settings after power outage
Auto DefrostPrevents coil freezing in low temperatures
Full Tank AlertLED indicator and auto shut-off when tank is full
MobilityFour swivel casters for easy movement

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place unit at least 12 inches from walls and furniture for proper airflow.
  2. Level surface: Ensure unit is level to allow water to flow correctly into tank.
  3. Power connection: Plug into dedicated 115V outlet; avoid extension cords.
  4. Continuous drainage: Attach 5/8" ID hose to drain port for automatic water removal (optional).

WARNING! Do not operate in temperatures below 41°F (5°C). Ensure proper ventilation around unit.

First-Time Setup

Plug in unit; follow initial setup steps.

  1. Install filter: Ensure washable filter is properly seated in filter compartment.
  2. Set humidity level: Press HUMIDITY button to set desired level (recommended 45-50%).
  3. Select mode: Choose between CONTINUOUS or AUTO mode based on needs.
  4. Check drainage: Ensure water tank is properly inserted or hose is connected securely.

CAUTION! Handle with care when moving; unit contains refrigerant.

Specifications

Controls and Settings

Access controls via digital panel. Power: ON/OFF button. Humidity Set: HUMIDITY button cycles 35%-85%. Mode: AUTO (maintains set humidity) or CONTINUOUS (runs constantly). Timer: 24-hour programmable on/off. Filter Reset: Indicates when filter needs cleaning. Full Tank: LED lights when tank needs emptying.

Display Icons: Power, Humidity %, Timer, Continuous Mode, Filter Alert, Full Tank, Defrost.

Operating Modes

AUTO Mode: Unit runs until set humidity is reached, then cycles on/off automatically. CONTINUOUS Mode: Runs continuously regardless of humidity level. Timer: Set unit to turn on/off at specific times. Defrost Mode: Automatically activates when coil temperature drops below freezing point.

  1. Select mode using MODE button.
  2. Adjust humidity with HUMIDITY button.
  3. Press TIMER to program on/off schedule.
  4. Monitor water tank; empty when FULL indicator lights.

Tip: Use CONTINUOUS mode for initial moisture removal in very damp conditions.

Maintenance & Cleaning

Unplug unit before maintenance.

  1. Clean filter: Remove and wash with warm water every 2 weeks; dry completely before reinstalling.
  2. Empty water tank: Remove tank, pour out water, clean with mild detergent if needed.
  3. Clean exterior: Wipe with damp cloth; do not use abrasive cleaners.
  4. Check drain hose: Ensure continuous drain hose is clear of obstructions.
  5. Coil cleaning: Gently vacuum condenser coil every season (accessible from rear grille).

CAUTION! Never operate without filter. Do not immerse unit in water.

Storage & Winterization

For long-term storage (e.g., winter months):

  1. Unplug unit and empty water tank completely.
  2. Clean filter and allow to dry.
  3. Clean interior and exterior surfaces.
  4. Cover unit or store in original box in dry location.
  5. Store upright; do not lay on side.

Note: Unit contains refrigerant; do not puncture or dispose in fire.

Safety Information

Read all instructions before use. Do not use in wet or damp locations. Keep cord away from heated surfaces. Do not block air intakes or outlets. Unplug before cleaning or maintenance. Do not operate with damaged cord or plug. This appliance is not intended for use by persons with reduced physical, sensory or mental capabilities.

WARNING! Risk of fire or electric shock. Do not use extension cords. Ensure proper grounding.

Regulatory Information

UL Listed. CSA Certified. This device complies with Part 15 of FCC Rules. Contains refrigerant R410A. For disposal, follow local regulations. Do not dispose with household waste. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onNo powerCheck outlet; ensure plug is secure; check circuit breaker.
Low dehumidificationDirty filter/room tempClean filter; ensure room temp above 41°F; check for air blockage.
Water leakingTank not seated/hoseEnsure tank properly inserted; check hose connections; ensure unit is level.
Loud noiseLoose parts/obstructionCheck for foreign objects; ensure unit is on level surface.
Full tank light on (empty tank)Float stuckRemove tank and check float mechanism moves freely.
Display not workingPower issueUnplug for 5 minutes, then reconnect; check outlet.
Unit cycles on defrost frequentlyLow temperatureMove to warmer area; normal operation below 65°F.

Reset: Unplug for 5 minutes to reset control board.

Service: 1-800-263-2629; www.danby.com