Danby DDR60AICP Dehumidifier Manual

The Danby DDR60AICP is a 60-pint capacity dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage option, electronic controls with digital display, auto-restart after power interruption, washable air filter, and energy-efficient operation. Suitable for areas up to 3000 sq. ft. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drainage 7. Operation Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic control panel with digital display, removable water bucket with full indicator, continuous drain port, washable air filter, caster wheels for mobility, and auto-defrost function.

FeatureDescription
Capacity60 pints per day (at 60°F, 60% RH)
Humidity ControlAutomatic with adjustable set point (35%-85%)
Digital DisplayShows current humidity, set point, and alerts
Water BucketRemovable with full bucket indicator and auto-shutoff
Continuous DrainGarden hose connection for continuous operation
Air FilterWashable mesh filter for improved air quality
Auto-RestartResumes previous settings after power outage
Auto-DefrostPrevents coil freezing in low temperatures
Timer Function24-hour on/off timer
MobilityFour caster wheels for easy movement

Installation

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place at least 6 inches from walls and furniture for proper airflow.
  2. Check components: Ensure water bucket is properly inserted and filter is clean.
  3. Power connection: Plug into dedicated 115V AC, 60Hz outlet.
  4. Drainage setup: For continuous drainage, attach garden hose to drain port.

WARNING! Do not use extension cords. Ensure unit is upright before operation.

First-Time Setup

Power on dehumidifier; follow initial setup steps.

  1. Set humidity level: Press HUMIDITY button to desired set point (recommended 45-50%).
  2. Select mode: Choose between CONTINUOUS or AUTO mode using MODE button.
  3. Timer setup: Use TIMER button to program on/off cycles if needed.
  4. Check operation: Verify compressor starts and air flows from vents.

CAUTION! Allow unit to stand upright for 24 hours if transported horizontally.

Specifications

Controls and Settings

Control Panel: POWER, MODE, HUMIDITY, FAN SPEED, TIMER, FILTER RESET.

Display Indicators: Current humidity, set point, bucket full, filter clean, timer, defrost mode.

Modes: CONTINUOUS (runs constantly), AUTO (cycles based on humidity set point). Fan Speed: HIGH or LOW. Humidity Control: Adjustable from 35% to 85% in 5% increments. Timer: 24-hour programmable on/off timer. Filter Reset: Resets filter maintenance indicator after cleaning.

Connecting Drainage

For continuous operation, use garden hose drainage.

  1. Turn off and unplug unit.
  2. Remove drain cap from rear drain port.
  3. Attach standard 5/8" garden hose (not included).
  4. Route hose to floor drain or suitable drainage area.
  5. Ensure hose has downward slope without kinks.

Tip: For bucket operation, empty before "Bucket Full" light activates.

Operation Modes

Two main operating modes for different needs.

  1. AUTO Mode: Unit cycles on/off to maintain set humidity level.
  2. CONTINUOUS Mode: Runs continuously regardless of humidity level.
  3. Fan Speed: Select HIGH for maximum dehumidification or LOW for quiet operation.
  4. Timer: Set to turn unit on/off at specific times.
  5. Defrost Mode: Automatically activates when coil temperature drops below 41°F.

WARNING! Do not operate below 41°F without auto-defrost function active.

Maintenance

Regular maintenance ensures optimal performance.

Care & Cleaning

Unplug before cleaning. Use mild detergent and damp cloth only.

CAUTION! Do not use abrasive cleaners, solvents, or water spray on controls. Never immerse unit in water.

Regulatory Information

UL Listed. FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629. This product contains refrigerant that must be disposed of properly by certified technicians.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/bucket fullCheck power connection; empty water bucket; reset circuit breaker.
Poor dehumidificationDirty filter/extreme conditionsClean air filter; ensure room temperature above 41°F; check for closed doors/windows.
Water leakageImproper bucket placement/hose connectionEnsure bucket fully inserted; check hose for leaks/kinks; level unit.
Loud noiseLoose parts/foreign objectsCheck for loose panels; ensure unit is level; remove objects near fan.
Display not workingPower issueCheck power supply; unplug for 10 minutes then restart.
Frost on coilsLow temperatureAuto-defrost should activate; move to warmer area if below 41°F.

Reset: Unplug for 10 minutes to reset electronic controls.

Service: 1-800-263-2629; www.danby.com

Danby DDR60AICP Dehumidifier Manual © - All Rights Reserved 2025