Danby DDR60RGDD Dehumidifier Manual

The Danby DDR60RGDD is a 60-pint dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage option, washable air filter, digital display with humidity readout, 24-hour timer, auto-restart function, and energy-efficient operation. Suitable for areas up to 3000 sq ft. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drainage 7. Operating Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, washable air filter, water collection bucket with full indicator, continuous drainage port, casters for mobility, and auto-defrost function.

FeatureDescription
Digital control panelLED display with humidity readout and control buttons
Washable air filterRemovable filter for easy cleaning
Water collection bucketRemovable 2-gallon bucket with full indicator and auto-shutoff
Continuous drainage portFor hose connection to drain water automatically
CastersFour wheels for easy mobility
Auto-defrost functionPrevents coil freezing in low temperatures
24-hour timerProgrammable on/off cycles
Auto-restartResumes previous settings after power interruption
Humidity controlAdjustable from 35% to 85% relative humidity
Energy efficientENERGY STAR certified operation

Installation

Unpack and inspect contents. Place on level surface.

  1. Position unit: Allow at least 12 inches clearance on all sides for proper airflow.
  2. Install filter: Ensure washable air filter is properly seated in front grille.
  3. Check bucket: Ensure water collection bucket is correctly inserted and locked.
  4. Plug into grounded 115V AC outlet.

WARNING! Do not use extension cords. Ensure proper ventilation around unit.

First-Time Setup

Power on dehumidifier; follow control panel prompts.

  1. Set humidity level: Press HUMIDITY button to select desired level (40-50% recommended).
  2. Select fan speed: Choose HIGH or LOW setting based on need.
  3. Set timer (optional): Use TIMER button to program on/off cycles.
  4. Enable continuous drainage (optional): Connect hose to drainage port.

CAUTION! Do not operate in temperatures below 41°F (5°C).

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, FILTER RESET.

Display Indicators: Current humidity, set humidity, bucket full, filter clean, timer, defrost mode.

Humidity Control: Adjust between 35% and 85% RH. Fan Speed: HIGH for maximum dehumidification, LOW for quiet operation. Timer: Set 1-24 hours for automatic start/stop. Filter Reset: Press after cleaning filter. Auto-defrost: Activates automatically when needed.

Connecting Drainage

Continuous drainage option for unattended operation.

  1. Turn off and unplug unit.
  2. Remove drain plug from back of unit.
  3. Connect 5/8" ID hose (not included) to drainage port.
  4. Route hose to floor drain or suitable drainage location.
  5. Ensure hose has downward slope without kinks.

Tip: When using continuous drainage, bucket can remain in place as backup.

Operating Modes

Multiple operation modes for different needs.

  1. Normal Mode: Runs continuously until set humidity is reached.
  2. Timer Mode: Set specific operating hours (1-24 hours).
  3. Continuous Mode: Runs continuously regardless of humidity (for very damp areas).
  4. Auto Mode: Unit automatically adjusts operation based on room humidity.
  5. Defrost Mode: Automatically activates when coil temperature drops below freezing point.

WARNING! Do not block air intake or exhaust. Keep doors and windows closed for best performance.

Maintenance

Regular maintenance ensures optimal performance.

  1. Clean filter every 2 weeks: Remove, wash with mild detergent, dry completely.
  2. Empty bucket regularly: When full indicator lights, remove and empty bucket.
  3. Clean exterior: Wipe with damp cloth, then dry.
  4. End-of-season storage: Empty bucket, clean filter, coil, and housing. Store upright in dry location.

Care & Cleaning

Unplug before cleaning. Use only mild detergent and water; no harsh chemicals.

CAUTION! Never immerse unit in water. Do not use gasoline, thinners, or abrasive cleaners.

Regulatory Information

ETL listed to UL standard 474. ENERGY STAR certified. FCC Part 15: Class B digital device. This product contains refrigerant R-410A. For proper disposal, consult local regulations. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/bucket fullCheck power connection; ensure bucket is properly seated and empty.
Reduced performanceDirty filter/extreme tempsClean air filter; ensure room temperature is within operating range.
Bucket full light onBucket full/improperly seatedEmpty bucket; ensure it's correctly inserted and locked.
Unit freezing upLow temperatureAuto-defrost should activate; move to warmer location if below 41°F.
Water leakageBucket not seated/hose issueCheck bucket placement; ensure drainage hose is properly connected.
Unusual noiseLoose parts/fan obstructionCheck for loose panels; ensure nothing is blocking fan.

Reset: Unplug for 5 minutes, then restart.

Service: 1-800-263-2629; www.danby.com

Danby DDR60RGDD Dehumidifier Manual © - All Rights Reserved 2025