Danby Premiere DDR35E Dehumidifier Manual

The Danby Premiere DDR35E is a high-capacity, energy-efficient dehumidifier designed for residential and light commercial use. It features a 35-pint per day removal capacity (at AHAM conditions), digital humidity readout, auto-defrost, continuous drain option, washable filter, and quiet operation. Suitable for areas up to 1500 sq ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Storage Instructions 9. Safety Information 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel with humidity display, 2.1-gallon water tank with full indicator, washable air filter, continuous drain hose connection, casters for mobility, and auto-restart function.

FeatureDescription
Digital Humidity DisplayShows current room humidity and set point
Auto DefrostPrevents coil freezing in low temperatures
Continuous Drain OptionFor hose connection to floor drain or sink
Washable Air FilterCaptures dust and airborne particles
Full Tank Alert & Auto ShutoffStops operation when tank is full
24-Hour TimerProgram on/off cycles
Turbo ModeMaximum moisture removal speed
Quiet OperationLow noise design for living spaces
Energy EfficientENERGY STAR® certified
Casters & HandlesEasy mobility between rooms

Installation & Placement

Unpack and inspect contents. Place on level, stable floor.

  1. Positioning: Place at least 6 inches from walls and furniture for proper airflow.
  2. Level Surface: Ensure unit is level for correct operation and water collection.
  3. Drain Options: Use built-in tank or connect drain hose to continuous drain port.
  4. Power Connection: Plug into dedicated 115V AC, 60Hz outlet. Do not use extension cord.

WARNING! Do not place in areas below 41°F (5°C). Ensure adequate ventilation around unit.

First-Time Setup

Power on dehumidifier; configure initial settings.

  1. Install filter: Ensure washable filter is properly seated in front grille.
  2. Set humidity level: Press HUMIDITY SET button to desired RH% (30-80%).
  3. Select mode: Choose between Continuous, Auto, or Turbo mode.
  4. Check drain: Place empty tank or connect drain hose securely.

CAUTION! Handle with care when moving; unit contains refrigerant.

Specifications

Controls and Settings

Control Panel: POWER, MODE, HUMIDITY SET, TIMER, TURBO, FILTER RESET.

Display Indicators: Current humidity, Set point, Full tank, Filter clean, Defrost, Timer.

Humidity Control: Set between 30-80% RH in 5% increments. Modes: Auto (maintains set point), Continuous (runs constantly), Turbo (maximum dehumidification). Timer: Program 1-24 hours for automatic start/stop. Filter Alert: Illuminates when filter needs cleaning (reset after cleaning).

Operation Modes

Auto Mode: Unit cycles on/off to maintain set humidity level. Continuous Mode: Runs continuously regardless of humidity. Turbo Mode: Fan runs at highest speed for fastest moisture removal.

  1. Select mode with MODE button.
  2. Adjust humidity set point as needed.
  3. Monitor water tank; empty when full or use continuous drain.
  4. Use timer for energy-saving operation.

Tip: For optimal efficiency, keep doors and windows closed during operation.

Maintenance & Cleaning

Regular maintenance ensures peak performance and longevity.

  1. Clean filter every 2 weeks: Remove, wash with warm water, dry completely.
  2. Empty water tank regularly; clean with mild detergent monthly.
  3. Wipe exterior with soft, damp cloth. Do not use abrasive cleaners.
  4. Check drain hose for clogs if using continuous drain.
  5. Inspect grille and coils for dust buildup; vacuum if necessary.

WARNING! Unplug unit before any maintenance. Never immerse in water.

Storage Instructions

For seasonal storage or extended non-use:

  1. Unplug unit and empty water tank completely.
  2. Clean filter and tank; allow all parts to dry thoroughly.
  3. Coil drain hose neatly if attached.
  4. Store in upright position in cool, dry place.
  5. Cover to prevent dust accumulation.

CAUTION! Store in area where temperature remains above freezing.

Safety Information

Important safety precautions for operation and maintenance.

DANGER! Risk of fire or explosion. Do not puncture refrigerant tubing.

Regulatory Information

UL Listed. ENERGY STAR® certified. Complies with FCC Part 15 Class B. Manufactured for Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629. This product contains fluorinated greenhouse gases covered by the Kyoto Protocol.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/full tankCheck power outlet; ensure tank is empty and properly seated.
Reduced moisture removalDirty filter/extreme conditionsClean filter; ensure room temp is between 41-95°F.
Water leakageImproper placement/damageEnsure unit is level; check tank for cracks; secure drain hose.
Loud noise/vibrationUneven surface/loose partsPlace on level floor; check for loose panels or foreign objects.
Display shows "CF"Filter needs cleaningClean filter and press FILTER RESET button.
Frost on coilsLow temperatureAuto-defrost should activate; move to warmer area if persistent.

Reset: Unplug for 5 minutes, then restart.

Service: 1-800-263-2629; www.danby.com