Danby Premiere DDR45A2GP Dehumidifier Manual

The Danby Premiere DDR45A2GP is a 45-pint dehumidifier designed for residential use, featuring automatic humidity control, continuous drain capability, auto-restart after power interruption, washable air filter, digital controls with LED display, 24-hour timer, and quiet operation. Ideal for basements, living areas, and other spaces up to 3000 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Draining Options 9. Energy Saving Tips 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, Water tank with full indicator, Continuous drain hose connection, Washable air filter, Casters for mobility, Handle for transport.

FeatureDescription
Digital Control PanelLED display for humidity level, timer, and settings
45-Pint CapacityRemoves up to 45 pints per day at 80°F/60% RH
Automatic Humidity ControlSet desired humidity level (35%-85%)
Continuous Drain OptionGravity drain hose connection (hose not included)
Auto-RestartResumes previous settings after power outage
24-Hour TimerProgram on/off times
Washable Air FilterCaptures dust and airborne particles
Full Tank Alert & Auto Shut-OffStops operation when tank is full
Quiet OperationLow noise level for residential use
Casters & HandleEasy mobility between rooms

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Choose location: Place in center of room, away from walls/furniture (minimum 12 inches clearance).
  2. Ensure proper airflow: Keep air inlet and outlet grilles unobstructed.
  3. Check environment: Operate in temperatures between 41°F and 95°F.
  4. Position near drain: If using continuous drain, place near floor drain or sink.
  5. Plug into dedicated 115V AC outlet.

WARNING! Do not use in confined spaces or near heat sources. Ensure unit is upright before operating.

First-Time Setup

Power on dehumidifier; follow initial setup steps.

  1. Install air filter: Ensure washable filter is properly seated.
  2. Set humidity level: Press HUMIDITY button to set desired level (recommended 45-50%).
  3. Select fan speed: Choose HIGH or LOW fan setting.
  4. Set timer (optional): Program 24-hour on/off schedule.
  5. Check drain options: Install drain hose for continuous use or use water tank.

CAUTION! Handle with care when moving; use two people if necessary.

Specifications

Controls and Settings

Access controls via digital panel. Front Panel: POWER, HUMIDITY, FAN SPEED, TIMER, FILTER RESET.

Display Indicators: Current humidity, Set humidity, Timer, Full tank, Filter clean, Defrost.

Humidity Control: Set between 35%-85% RH. Fan Speed: HIGH for maximum dehumidification, LOW for quiet operation. Timer: 24-hour programmable on/off. Filter Reset: Press after cleaning air filter. Auto Defrost: Automatically activates when coil frosts.

Operation Modes

Normal Mode: Set desired humidity; unit runs until level is reached. Continuous Mode: Runs continuously regardless of humidity level. Timer Mode: Program specific operating times.

  1. Press POWER to turn on.
  2. Set humidity using HUMIDITY buttons.
  3. Select fan speed (HIGH/LOW).
  4. For continuous operation, set humidity to lowest setting.
  5. Monitor water tank; empty when full indicator lights.

Tip: Close windows and doors for optimal performance.

Maintenance & Cleaning

Regular maintenance ensures optimal performance.

  1. Clean air filter every 2 weeks: Remove, wash with warm water, dry completely.
  2. Empty water tank regularly: Lift straight up to remove; pour out water.
  3. Clean exterior: Unplug unit, wipe with damp cloth.
  4. Clean water tank monthly: Use mild detergent, rinse thoroughly.
  5. Check drain hose: Ensure continuous drain hose is clear of obstructions.

WARNING! Always unplug before cleaning. Do not use harsh chemicals.

Draining Options

Two methods: Water tank or continuous drain.

Water Tank: Unit stops when tank is full (indicator lights). Remove tank by lifting straight up, pour out water, replace securely.

Continuous Drain: Connect 5/8" ID hose to drain port (hose not included). Ensure hose runs downward to floor drain or sink. Gravity drain only - no pump included.

CAUTION! Do not tilt unit with full water tank. Ensure drain hose has no kinks.

Energy Saving Tips

Regulatory Information

UL Listed: Meets safety standards for household use. Energy Star: Meets energy efficiency guidelines. FCC Part 15: Class B digital device; complies with interference limits. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/full tankCheck power cord; ensure outlet works; empty water tank.
Poor dehumidificationDirty filter/extreme tempsClean air filter; ensure room temp between 41°F-95°F.
Water leakingImproper tank placementEnsure tank is properly seated; check drain hose connection.
Loud noiseUneven surface/obstructionPlace on level surface; check for objects near fan.
Frost on coilsLow temperatureAuto defrost will activate; move to warmer area if persistent.
Display not workingPower interruptionUnplug for 5 minutes, then restart; check power source.

Reset: Unplug for 10 minutes to reset control board.

Service: 1-800-263-2629; www.danby.com