Danby Premiere DDR5011 Dehumidifier Manual

The Danby Premiere DDR5011 is a 50-pint capacity dehumidifier designed for residential use. It features electronic controls with a digital display, automatic humidity sensing, continuous drain option, auto-restart, washable air filter, and a 24-hour timer. Suitable for areas up to 3000 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance 8. Care & Cleaning 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Electronic control panel, Digital display, Water collection bucket, Washable air filter, Continuous drain hose connection, Casters for mobility.

FeatureDescription
Capacity50 pints per day (at 80°F, 60% RH)
Control PanelElectronic touch controls with LED display
Humidity ControlAutomatic humidity sensing from 35% to 85%
Timer24-hour programmable on/off timer
Auto RestartResumes previous settings after power interruption
Continuous DrainOption for hose connection (hose not included)
Air FilterWashable mesh filter for air purification
Bucket Full AlertVisual indicator and automatic shut-off
MobilityFour swivel casters for easy movement
Defrost FunctionAuto-defrost for low-temperature operation

Installation

Unpack and inspect contents. Place on level, stable surface.

  1. Remove packaging: Remove all tape and protective materials.
  2. Positioning: Place at least 12 inches from walls and furniture for proper airflow.
  3. Check filter: Ensure air filter is properly installed.
  4. Power connection: Plug into dedicated 115V AC, 60Hz outlet.
  5. Drain option: Attach 5/8" ID hose to continuous drain port if desired.

WARNING! Do not use extension cords. Ensure proper ventilation around unit.

First-Time Setup

Plug in unit; control panel will illuminate.

  1. Set humidity level: Press HUMIDITY button to select desired level (40-60% recommended).
  2. Select fan speed: Press FAN button for HIGH or LOW speed.
  3. Timer setup: Press TIMER to program automatic start/stop times.
  4. Bucket check: Ensure bucket is properly seated and empty.
  5. Continuous drain: Connect hose if using permanent drainage.

CAUTION! Handle bucket carefully to avoid spills. Unit must be upright for 24 hours before first use if tilted during transport.

Specifications

Controls and Settings

Control Panel: POWER, MODE, HUMIDITY, FAN, TIMER, FILTER RESET.

Display Indicators: Current humidity, Set humidity, Timer settings, Bucket full, Filter clean, Defrost mode.

Humidity Setting: Adjust from 35% to 85% in 5% increments. Fan Speed: HIGH for maximum dehumidification, LOW for quiet operation. Mode Selection: CONTINUOUS (runs constantly), AUTO (cycles based on humidity setting). Timer: Program start/stop times in 1-hour increments. Filter Reset: Press after cleaning filter to reset reminder light.

Operation Modes

AUTO Mode: Unit runs when humidity exceeds set point. CONTINUOUS Mode: Runs continuously regardless of humidity. Laundry Mode: Increases fan speed for faster drying in laundry areas.

  1. Press POWER to turn unit on.
  2. Select MODE to choose AUTO, CONTINUOUS, or LAUNDRY.
  3. Set desired humidity level with HUMIDITY button.
  4. Select fan speed with FAN button.
  5. Monitor water collection: Empty bucket when FULL light illuminates.

Tip: For maximum efficiency, keep doors and windows closed during operation.

Maintenance

Regular maintenance ensures optimal performance.

  1. Empty bucket: Remove and empty water collection bucket regularly.
  2. Clean filter: Remove and wash air filter every 2 weeks with warm water.
  3. Clean exterior: Wipe cabinet with damp cloth.
  4. Check drain hose: Ensure continuous drain hose is clear of obstructions.
  5. Off-season storage: Clean thoroughly, empty all water, store in upright position.

WARNING! Always unplug unit before performing any maintenance. Do not use harsh chemicals.

Care & Cleaning

Unplug before cleaning. Clean air filter every 2 weeks. Wipe exterior with soft, damp cloth.

CAUTION! Do not immerse unit in water. Do not use abrasive cleaners. Allow filter to dry completely before reinstalling.

Regulatory Information

UL Listed. CSA Certified. This product meets ENERGY STAR® requirements for energy efficiency. Manufactured for Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629. This appliance contains R410A refrigerant. Dispose of according to local regulations.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/bucket fullCheck power connection; ensure bucket is empty and properly seated.
Poor dehumidificationFilter/door/ temperatureClean air filter; keep doors/windows closed; check room temperature (above 41°F).
Water leakageBucket/hose connectionEnsure bucket is properly positioned; check hose connections for continuous drain.
Loud noiseUneven surface/fanPlace on level surface; check for obstructions in fan area.
Frost on coilsLow temperatureAuto-defrost should activate; if persistent, move to warmer area.
Error codes on displaySensor/system issueUnplug for 5 minutes, then restart. If persists, contact service.

Reset: Unplug for 5 minutes to reset electronic controls.

Service: 1-800-263-2629; www.danby.com

Danby Premiere DDR5011 Dehumidifier Manual © - All Rights Reserved 2025