Danby Premiere DDR50A2GP Dehumidifier Manual

The Danby Premiere DDR50A2GP is a 50-pint dehumidifier designed for medium to large rooms, featuring electronic controls, a continuous drain option, auto-restart, auto-defrost, a 24-hour timer, and a washable filter. It operates on 115V/60Hz power and includes a built-in humidistat for precise moisture control. Below are key sections covering safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drain Hose 7. Operating Modes 8. Maintenance & Cleaning 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Electronic control panel, built-in humidistat, continuous drain port, removable water bucket with full-bucket alert, washable air filter, auto-defrost, and 24-hour timer.

FeatureDescription
Electronic ControlsTouchpad for setting humidity level, mode, and timer
HumidistatAutomatically maintains set humidity level (35%-85% RH)
Continuous Drain PortFor hose connection to allow unattended operation
Removable Water Bucket2.1-gallon capacity with handle and full indicator
Washable Air FilterCaptures dust and particles; reusable after cleaning
Auto-DefrostPrevents coil freezing in low temperatures
Auto-RestartResumes previous settings after power interruption
24-Hour TimerProgram on/off times for energy savings
Power Cord StorageBuilt-in wraps for neat storage
Wheels & HandlesFor easy mobility between rooms

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Choose location: Place in center of room, away from walls/furniture for airflow.
  2. Ensure clearance: At least 12 inches from walls, curtains, and other obstructions.
  3. Check environment: Operate in temperatures between 41°F (5°C) and 95°F (35°C).
  4. Plug into dedicated 115V outlet: Do not use extension cords.

WARNING! Do not place near heat sources or in direct sunlight. Ensure unit is upright before operation.

First-Time Setup

Power on dehumidifier; follow initial setup steps.

  1. Install filter: Ensure washable filter is securely in place.
  2. Set humidity: Press HUMIDITY button to desired level (start at 50% RH).
  3. Select mode: Choose CONTINUOUS or AUTO mode based on needs.
  4. Set timer (optional): Program on/off times using TIMER button.
  5. Check drain options: Use bucket or connect hose for continuous drainage.

CAUTION! Allow unit to stand upright for 24 hours if tilted during transport.

Specifications

Controls and Settings

Access settings via electronic control panel. Buttons: POWER, MODE, HUMIDITY, TIMER, FAN SPEED.

Display Indicators: Power, Bucket Full, Defrost, Humidity Set Point, Timer, Fan Speed.

Modes: CONTINUOUS (runs until turned off), AUTO (cycles based on humidistat). Fan Speeds: HIGH (faster dehumidification), LOW (quieter operation). Timer: Set 1-24 hours for automatic start/stop. Humidity Setting: Adjust in 5% increments from 35% to 85%.

Connecting Drain Hose

For continuous drainage, use 5/8" inner diameter garden hose (not included).

  1. Turn off and unplug unit.
  2. Remove drain cap from back of unit.
  3. Insert hose into drain port; secure with clamp if provided.
  4. Route hose to floor drain, sink, or sump pump (ensure downward slope).
  5. Plug in and turn on; unit will drain automatically.

Tip: Ensure hose is free of kinks and blockages for proper flow.

Operating Modes

Supports multiple modes for efficient moisture removal.

  1. AUTO Mode: Unit cycles on/off to maintain set humidity level.
  2. CONTINUOUS Mode: Runs continuously until manually turned off or bucket is full.
  3. Timer Operation: Set to turn on/off at specific times (e.g., before returning home).
  4. Fan Speed: Select HIGH for maximum dehumidification, LOW for quiet operation.
  5. Defrost Cycle: Automatically activates when coil temperature drops below 41°F (5°C).

WARNING! Do not operate in temperatures below 41°F (5°C) without auto-defrost feature enabled.

Maintenance & Cleaning

Unplug before cleaning. Regular maintenance ensures optimal performance.

  1. Clean filter every 2 weeks: Remove, wash with mild detergent, rinse, dry completely.
  2. Empty bucket regularly: Pour out water; clean with soft cloth and mild detergent.
  3. Clean exterior: Wipe with damp cloth; do not use abrasive cleaners.
  4. Check drain hose: Ensure it is clear of debris if using continuous drain.
  5. End-of-season storage: Empty bucket, clean unit, wrap cord, store in dry place.

CAUTION! Never immerse unit in water. Do not use chemicals on filter.

Regulatory Information

UL Listed; complies with U.S. safety standards. Energy Star certified for energy efficiency. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onNo powerCheck outlet; ensure plug is secure; test outlet with another device.
Red bucket light onBucket full or not seatedEmpty bucket; ensure it is properly inserted.
Low dehumidificationDirty filter, low tempClean filter; ensure room temp is above 41°F (5°C).
Unit cycling on/off frequentlyHumidistat set too highLower humidity setting; ensure unit is not near moisture source.
Water leakingBucket misaligned, hose looseRe-seat bucket; check hose connection; ensure unit is level.
Unusual noiseLoose parts, fan obstructionCheck for loose panels; ensure filter is clean and properly installed.
Frost on coilsLow room temperatureAuto-defrost should activate; move unit to warmer area if persistent.

Reset: Unplug for 5 minutes, then restart.

Service: 1-800-263-2629; www.danby.com