Danby Premiere DDR50B3WP Dehumidifier Manual

The Danby Premiere DDR50B3WP is a high-capacity 50-pint dehumidifier designed for residential use, featuring a sleek white cabinet, electronic controls with digital display, continuous drain option, auto-restart, washable filter, and energy-efficient operation. Ideal for basements, living areas, and other spaces up to 3000 sq ft. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Modes 7. Maintenance & Cleaning 8. Continuous Drain Option 9. Energy Saving Tips 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic control panel with digital display, 50-pint moisture removal capacity (at 80°F/60% RH), washable air filter, built-in humidistat, 24-hour timer, auto-defrost, auto-restart, full bucket alert, and continuous drain option.

FeatureDescription
CapacityRemoves up to 50 pints per day (AHAM verified)
Control PanelElectronic touch controls with LED display
HumidistatAdjustable from 35% to 85% relative humidity
Timer24-hour programmable on/off timer
Auto-DefrostPrevents coil freezing in low temperatures
Auto-RestartResumes operation after power interruption
Continuous DrainGarden hose connection for unattended operation
FilterWashable air filter for easy maintenance
Bucket Full AlertLED indicator and auto-shutoff when bucket is full
Wheels & HandlesIntegrated for easy mobility

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Clear area: Ensure at least 12-18 inches of clearance on all sides for proper airflow.
  2. Check power: Use a dedicated 115V/60Hz outlet; avoid extension cords.
  3. Position unit: Place in center of room or area with highest humidity.
  4. Level surface: Ensure unit is level to prevent water leakage.
  5. Prepare drain hose: If using continuous drain, attach 5/8" garden hose to drain port.

WARNING! Do not place near heat sources or in direct sunlight. Ensure bucket is properly seated before operation.

First-Time Setup

Plug in unit; allow to stand upright for 24 hours if transported horizontally.

  1. Insert bucket: Ensure collection bucket is fully inserted and locked in place.
  2. Set humidity level: Press HUMIDITY button to set desired RH (start at 50%).
  3. Select fan speed: Choose HIGH for maximum moisture removal or LOW for quiet operation.
  4. Set timer (optional): Use TIMER button to program automatic on/off times.
  5. Start operation: Press POWER button to begin dehumidification.

CAUTION! Handle with care; unit contains refrigerant. Do not tilt or invert during operation.

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY (+/-), FAN SPEED (HIGH/LOW), TIMER, FILTER RESET.

Display Indicators: Current humidity, set point, fan speed, timer status, filter alert, bucket full, defrost mode.

Humidity Control: Adjust between 35%-85% RH in 5% increments. Fan Speed: HIGH for maximum dehumidification, LOW for quiet operation. Timer: Programmable 24-hour on/off schedule. Auto Mode: Unit automatically adjusts fan speed based on humidity level. Filter Reset: Press after cleaning filter to reset reminder light.

Operating Modes

Normal Mode: Set desired humidity level; unit runs until target is reached. Continuous Mode: Runs continuously regardless of humidity (for very damp areas). Laundry Mode: Higher fan speed for drying clothes in enclosed spaces. Smart Dry: Automatically adjusts settings for optimal moisture removal.

  1. Select mode using MODE button.
  2. Adjust settings as needed for current conditions.
  3. Monitor display for current humidity and operation status.

Tip: For energy savings, set humidity to 50-55% for most living spaces.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean filter: Remove and wash filter every 2-4 weeks with warm water.
  2. Empty bucket: When FULL indicator lights, turn off unit and empty bucket.
  3. Clean exterior: Wipe with damp cloth; do not use harsh chemicals.
  4. Clean coils: Use soft brush to remove dust from rear coils annually.
  5. Check drain hose: Ensure continuous drain hose is clear of obstructions.

WARNING! Always unplug unit before cleaning. Never immerse in water.

Continuous Drain Option

For unattended operation, use the continuous drain feature.

  1. Locate drain port on back of unit.
  2. Attach standard 5/8" garden hose (not included).
  3. Route hose to floor drain, sink, or sump pump.
  4. Ensure hose has downward slope without kinks.
  5. Remove bucket when using continuous drain.

Note: Unit will still display "FULL" indicator when bucket is removed; this is normal.

Energy Saving Tips

Close windows and doors during operation. Set humidity to 50-55% for comfort and efficiency. Use timer to run during peak humidity hours only. Clean filter regularly for optimal airflow. Place unit in coolest part of room for best performance.

CAUTION! Do not operate below 41°F; auto-defrost protects coils but reduces efficiency in cold temperatures.

Regulatory Information

ETL Listed: Meets safety standards for the United States and Canada. Energy Star Certified: Meets strict energy efficiency guidelines. AHAM Verified: Capacity verified per AHAM DH-1 testing standard. EPA Refrigerant: Uses R410A, which has zero ozone depletion potential. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningPower issue/bucket fullCheck power outlet; empty bucket; ensure bucket is properly seated.
Low moisture removalDirty filter/cold roomClean filter; ensure room temperature above 65°F; check for air leaks.
Water leakageImproper level/damageEnsure unit is level; check bucket for cracks; verify drain hose connection.
Loud noiseLoose parts/fan obstructionCheck for loose panels; ensure nothing is touching fan; place on level surface.
Display not workingPower interruptionUnplug for 5 minutes, then reconnect; check circuit breaker.
Ice on coilsLow temperatureAuto-defrost should activate; raise room temperature above 41°F.

Reset: Unplug for 5 minutes to reset electronic controls.

Service: 1-800-263-2629; www.danby.com

Danby Premiere DDR50B3WP Dehumidifier Manual © - All Rights Reserved 2025