The Danby Premiere DDR50B3WP is a high-capacity 50-pint dehumidifier designed for residential use, featuring a sleek white cabinet, electronic controls with digital display, continuous drain option, auto-restart, washable filter, and energy-efficient operation. Ideal for basements, living areas, and other spaces up to 3000 sq ft. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Electronic control panel with digital display, 50-pint moisture removal capacity (at 80°F/60% RH), washable air filter, built-in humidistat, 24-hour timer, auto-defrost, auto-restart, full bucket alert, and continuous drain option.
| Feature | Description |
|---|---|
| Capacity | Removes up to 50 pints per day (AHAM verified) |
| Control Panel | Electronic touch controls with LED display |
| Humidistat | Adjustable from 35% to 85% relative humidity |
| Timer | 24-hour programmable on/off timer |
| Auto-Defrost | Prevents coil freezing in low temperatures |
| Auto-Restart | Resumes operation after power interruption |
| Continuous Drain | Garden hose connection for unattended operation |
| Filter | Washable air filter for easy maintenance |
| Bucket Full Alert | LED indicator and auto-shutoff when bucket is full |
| Wheels & Handles | Integrated for easy mobility |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not place near heat sources or in direct sunlight. Ensure bucket is properly seated before operation.
Plug in unit; allow to stand upright for 24 hours if transported horizontally.
CAUTION! Handle with care; unit contains refrigerant. Do not tilt or invert during operation.
Control Panel: POWER, HUMIDITY (+/-), FAN SPEED (HIGH/LOW), TIMER, FILTER RESET.
Display Indicators: Current humidity, set point, fan speed, timer status, filter alert, bucket full, defrost mode.
Humidity Control: Adjust between 35%-85% RH in 5% increments. Fan Speed: HIGH for maximum dehumidification, LOW for quiet operation. Timer: Programmable 24-hour on/off schedule. Auto Mode: Unit automatically adjusts fan speed based on humidity level. Filter Reset: Press after cleaning filter to reset reminder light.
Normal Mode: Set desired humidity level; unit runs until target is reached. Continuous Mode: Runs continuously regardless of humidity (for very damp areas). Laundry Mode: Higher fan speed for drying clothes in enclosed spaces. Smart Dry: Automatically adjusts settings for optimal moisture removal.
Tip: For energy savings, set humidity to 50-55% for most living spaces.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always unplug unit before cleaning. Never immerse in water.
For unattended operation, use the continuous drain feature.
Note: Unit will still display "FULL" indicator when bucket is removed; this is normal.
Close windows and doors during operation. Set humidity to 50-55% for comfort and efficiency. Use timer to run during peak humidity hours only. Clean filter regularly for optimal airflow. Place unit in coolest part of room for best performance.
CAUTION! Do not operate below 41°F; auto-defrost protects coils but reduces efficiency in cold temperatures.
ETL Listed: Meets safety standards for the United States and Canada. Energy Star Certified: Meets strict energy efficiency guidelines. AHAM Verified: Capacity verified per AHAM DH-1 testing standard. EPA Refrigerant: Uses R410A, which has zero ozone depletion potential. For support, visit www.danby.com or contact 1-800-263-2629.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not running | Power issue/bucket full | Check power outlet; empty bucket; ensure bucket is properly seated. |
| Low moisture removal | Dirty filter/cold room | Clean filter; ensure room temperature above 65°F; check for air leaks. |
| Water leakage | Improper level/damage | Ensure unit is level; check bucket for cracks; verify drain hose connection. |
| Loud noise | Loose parts/fan obstruction | Check for loose panels; ensure nothing is touching fan; place on level surface. |
| Display not working | Power interruption | Unplug for 5 minutes, then reconnect; check circuit breaker. |
| Ice on coils | Low temperature | Auto-defrost should activate; raise room temperature above 41°F. |
Reset: Unplug for 5 minutes to reset electronic controls.
Service: 1-800-263-2629; www.danby.com