Danby Premiere DDR60A1CP Dehumidifier Manual

The Danby Premiere DDR60A1CP is a high-capacity 60-pint dehumidifier designed for residential use in spaces up to 1500 sq. ft. It features electronic controls with a digital display, a continuous drain option, auto-restart, a 24-hour timer, washable air filter, and a full-bucket alert with auto shut-off. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic control panel with digital display, removable water bucket with handle and full indicator, washable air filter, continuous drain hose connection, casters for mobility, and adjustable humidity settings.

FeatureDescription
Dehumidification Capacity60 pints per day (at 80°F, 60% RH)
Digital DisplayShows current humidity, set point, timer, and alerts
Electronic ControlsTouch buttons for settings and modes
Continuous Drain OptionGarden hose connection for automatic drainage
Auto RestartResumes previous settings after a power interruption
24-Hour TimerProgram on/off cycles
Full Bucket Alert & Auto Shut-OffStops operation and lights indicator when bucket is full
Washable Air FilterCaptures airborne particles; can be cleaned
Adjustable Humidity Set PointSet desired humidity level from 35% to 85%
MobilityFour casters for easy movement

Installation & Placement

Unpack and inspect contents. Place on a level, stable floor.

  1. Choose Location: Place in the center of the room or area with high humidity, away from walls and furniture for proper air circulation.
  2. Clearance: Ensure at least 12 inches of clearance on all sides, especially the air intake and exhaust.
  3. Check Floor: Surface must be level to ensure proper operation and bucket seating.
  4. Power Connection: Plug directly into a grounded 115V AC, 60Hz outlet. Do not use an extension cord.

WARNING! Do not place in an enclosed space or block air vents. Ensure the unit is upright for at least 24 hours before first use if it was tilted during transport.

First-Time Setup

Plug in the unit; the control panel will illuminate.

  1. Insert Bucket: Ensure the water collection bucket is correctly seated.
  2. Set Humidity: Press the HUMIDITY button to set your desired level (recommended 45-50% for comfort).
  3. Select Mode: Choose between CONTINUOUS (runs constantly) or AUTO (maintains set humidity).
  4. Set Timer (Optional): Use the TIMER button to program automatic start/stop times.
  5. Start Operation: Press the POWER button to begin dehumidification.

CAUTION! Handle the unit with care. Do not operate without the air filter installed.

Specifications

Controls and Settings

Access all functions via the electronic control panel on top of the unit.

Control Panel: POWER, HUMIDITY (+/-), MODE (Continuous/Auto), TIMER (Up/Down), FILTER ALERT RESET.

Display Icons: Power On, Bucket Full, Filter Clean, Timer Set, Continuous Mode, Auto Mode, Target Humidity, Current Humidity.

Settings: Humidity Set Point (35%-85%), 24-Hour Programmable Timer, Mode Selection (Continuous, Auto), Filter Reset Indicator.

Operation Modes

AUTO Mode: The unit cycles on and off automatically to maintain the set humidity level. This is the most energy-efficient setting for general use.

CONTINUOUS Mode: The compressor runs continuously until the bucket is full or the unit is turned off. Use for rapid moisture removal in very damp conditions.

  1. Press the MODE button to toggle between AUTO and CONTINUOUS.
  2. In AUTO mode, use the HUMIDITY buttons to set your desired level.
  3. The display shows both the current room humidity and the set point.

Tip: For best efficiency, close windows and doors in the room where the dehumidifier is operating.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Empty the Water Bucket: Remove, empty, and securely reinsert the bucket when the FULL indicator lights and the unit shuts off.
  2. Clean the Air Filter: Every two weeks or as needed. Remove, wash with warm soapy water, rinse, dry completely, and reinstall. Press and hold the FILTER button for 3 seconds to reset the alert.
  3. Clean the Exterior: Unplug the unit. Wipe the cabinet with a soft, damp cloth. Do not use harsh chemicals or abrasives.
  4. End-of-Season Cleaning: Before storage, empty the bucket and allow the interior to dry completely with the bucket removed.

WARNING! Always unplug the unit before performing any maintenance. Never operate without the air filter.

Drainage Options

Bucket Drainage: Standard method. Empty the bucket manually when full.

Continuous Drainage:

  1. Locate the drain outlet on the back of the unit.
  2. Remove the drain plug and store it safely.
  3. Connect a standard 5/8" inner diameter garden hose (not included). Ensure the hose runs downward to a floor drain or suitable outlet.
  4. The unit will now drain continuously; the bucket full alert and auto shut-off are disabled in this mode.

CAUTION! For continuous drain, the drain outlet must be higher than the end of the hose to prevent backflow. Ensure the hose is not kinked.

Care & Storage

When not in use for an extended period:

  1. Unplug the unit.
  2. Empty and dry the water bucket completely.
  3. Clean the air filter and let it dry.
  4. Coil the power cord neatly.
  5. Store the unit upright in a cool, dry place. Cover it to prevent dust accumulation.

CAUTION! Do not store the unit on its side or upside down. Never place heavy objects on top of it.

Regulatory Information

This dehumidifier complies with relevant U.S. safety standards. It uses refrigerant R410A. For your safety and to ensure compliance, do not modify the unit. Copyright and trademarks are property of Danby Products Inc. For support, visit www.danby.com or contact customer service at 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not startNo power / Bucket not seated / Full bucketCheck plug and outlet; Ensure bucket is correctly inserted; Empty bucket if full.
Little or no water collectionLow humidity / Cold room temp / Dirty filterRoom may already be dry; Unit works best above 65°F; Clean the air filter.
Unit runs but air feels warmNormal operationExhaust air is slightly warmer than room air. This is normal.
Loud or unusual noiseUneven floor / Loose parts / Dirty filterPlace on level surface; Check for loose panels; Clean air filter.
Error code on display (e.g., E1, E2)Sensor or system faultUnplug for 10 minutes, then restart. If code persists, contact service.
Filter light is onAir filter needs cleaningClean the washable air filter and press FILTER button to reset.

Reset: Unplug the unit for 10 minutes to reset the electronic control system.

Service: 1-800-263-2629; www.danby.com