Danby Premiere DDR60A1GP Dehumidifier Manual

The Danby Premiere DDR60A1GP is a 60-pint capacity dehumidifier designed for residential use, featuring electronic controls, a digital display, 24-hour timer, continuous drain option, auto-defrost, washable filter, and adjustable humidity settings. It operates on 115V/60Hz power and is ideal for medium to large rooms up to 3000 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance 8. Care & Cleaning 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Electronic control panel, Digital display, 60-pint water tank, Continuous drain hose connection, Washable air filter, Auto-restart function, Auto-defrost system.

FeatureDescription
Capacity60 pints per day (at 80°F, 60% RH)
Control PanelElectronic touch controls with LED display
Water TankFull tank indicator and auto shut-off
Continuous DrainHose connection for continuous operation
Timer24-hour programmable timer
Humidity ControlAdjustable from 35% to 80% relative humidity
FilterWashable air filter for easy maintenance
Auto-DefrostAutomatic operation in low temperatures
Power Cord6-foot power cord with storage wrap
Wheels & HandlesBuilt-in for easy mobility

Installation

Unpack and inspect contents. Place on level surface away from walls and furniture.

  1. Positioning: Place unit on level floor with at least 12 inches clearance on all sides.
  2. Water Tank Installation: Ensure tank is properly seated and locked in place.
  3. Continuous Drain Option: Connect 5/8" ID hose to drain outlet (hose not included).
  4. Power Connection: Plug into grounded 115V outlet. Do not use extension cord.

WARNING! Ensure unit is upright for at least 24 hours before first use if transported on its side. Keep away from heat sources and direct sunlight.

First-Time Setup

Power on dehumidifier; configure initial settings.

  1. Initial Power: Plug in unit. Display will show current room humidity.
  2. Set Desired Humidity: Press HUMIDITY button to set target (40-50% recommended).
  3. Timer Setup: Press TIMER button to program on/off times if needed.
  4. Mode Selection: Choose between Continuous, Auto, or Dry modes.

CAUTION! Do not operate in temperatures below 41°F (5°C). Ensure water tank is empty before first use.

Specifications

Controls and Settings

Control Panel: POWER, MODE, HUMIDITY, FAN SPEED, TIMER, FILTER RESET.

Display Indicators: Current humidity, Set humidity, Timer, Full tank, Filter clean, Defrost mode.

Humidity Settings: Adjustable from 35% to 80% in 5% increments. Fan Speed: High or Low settings. Modes: Continuous (runs constantly), Auto (maintains set humidity), Dry (for laundry rooms). Timer: Program on/off times in 1-hour increments up to 24 hours. Filter Reset: Press after cleaning filter to reset indicator.

Operation Modes

Three operating modes for different needs.

  1. Auto Mode: Unit runs until set humidity is reached, then cycles on/off automatically.
  2. Continuous Mode: Runs continuously regardless of humidity level.
  3. Dry Mode: Optimized for drying laundry or very damp areas.

Tip: Use Auto mode for energy efficiency. Empty water tank regularly or use continuous drain.

Maintenance

Regular maintenance ensures optimal performance.

  1. Water Tank: Empty when full tank indicator lights. Clean monthly with mild detergent.
  2. Air Filter: Clean every 2 weeks or when FILTER light illuminates.
  3. Exterior Cleaning: Wipe with damp cloth. Never use harsh chemicals.
  4. End of Season: Drain completely, clean tank and filter, store upright in dry place.

WARNING! Always unplug unit before cleaning. Do not immerse in water.

Care & Cleaning

Unplug before cleaning. Use mild detergent and soft cloth only.

CAUTION! Do not use gasoline, thinners, or abrasive cleaners. Keep electrical components dry.

Regulatory Information

UL Listed. CSA Certified. Meets DOE energy efficiency standards. This product contains refrigerant that must be disposed of properly by certified technicians. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/full tankCheck power connection; ensure tank is empty and properly seated.
Reduced dehumidificationDirty filter/extreme tempsClean air filter; ensure room temperature is within operating range.
Water leakageTank not seated/drain hoseEnsure tank is properly locked; check drain hose connection.
Loud noiseUneven surface/obstructionPlace on level surface; check for objects near fan.
Frost on coilsLow temperatureAuto-defrost should activate; move to warmer area if persistent.

Reset: Unplug for 5 minutes, then restart.

Service: 1-800-263-2629; www.danby.com

Danby Premiere DDR60A1GP Dehumidifier Manual © - All Rights Reserved 2025