Danby Premiere DDR60A2GP Dehumidifier Manual

The Danby Premiere DDR60A2GP is a high-capacity 60-pint dehumidifier designed for residential use in areas up to 3000 sq. ft. It features automatic humidity control, continuous drain option, 24-hour timer, washable filter, auto-restart, and digital controls with LED display. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Energy Efficiency Tips 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, LED display, Water tank with full indicator, Continuous drain hose connection, Washable air filter, Casters for mobility.

FeatureDescription
Humidity ControlAutomatic humidity sensing with adjustable set point (35%-85%)
Water TankRemovable 60-pint capacity with full indicator and auto shut-off
Continuous DrainHose connection for permanent drainage option
24-Hour TimerProgrammable on/off timer for energy savings
Air FilterWashable mesh filter for improved air quality
Auto RestartResumes previous settings after power interruption
Defrost FunctionAutomatic defrost in low temperature conditions
Control LockPrevents accidental setting changes
MobilityFour swivel casters for easy room-to-room movement
DisplayLED showing current humidity, settings, and alerts

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place at least 6 inches from walls and furniture for proper airflow.
  2. Environment: Operate in temperatures between 41°F (5°C) and 95°F (35°C).
  3. Power Connection: Plug directly into grounded 115V outlet; avoid extension cords.
  4. Initial Setup: Allow unit to stand upright for 24 hours if transported horizontally.

WARNING! Do not place in confined spaces or block air vents. Ensure proper ventilation.

First-Time Setup

Power on dehumidifier; configure initial settings.

  1. Set Humidity Level: Press HUMIDITY button to select desired level (45-50% recommended).
  2. Select Fan Speed: Choose HIGH or LOW setting based on room size and humidity.
  3. Timer Setup: Program 24-hour timer if needed for automatic operation.
  4. Check Drainage: Install drain hose if using continuous drainage option.

CAUTION! Handle water tank carefully when full; empty before moving unit.

Specifications

Controls and Settings

Access controls via digital panel. Front Panel: POWER, HUMIDITY, FAN SPEED, TIMER, FILTER RESET, LOCK.

Display Indicators: Current humidity, Set point, Tank full, Filter clean, Defrost mode, Timer status.

Humidity Control: Adjust between 35%-85% in 5% increments. Fan Speed: HIGH for maximum dehumidification, LOW for quiet operation. Timer: Program on/off cycles in 1-hour increments. Filter Alert: LED indicates when filter needs cleaning. Control Lock: Press and hold LOCK for 3 seconds to enable/disable.

Operation Modes

Normal Mode: Maintains set humidity level automatically. Continuous Mode: Runs continuously regardless of humidity (for very damp areas). Laundry Mode: Higher fan speed for drying clothes. Timer Mode: Scheduled operation for energy efficiency.

  1. Select mode using MODE button.
  2. Adjust settings as needed for each mode.
  3. Monitor LED display for current status.

Tip: Use Laundry Mode in enclosed rooms with wet clothing for faster drying.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean Filter: Remove and wash filter every 2 weeks; dry completely before reinstalling.
  2. Empty Tank: Empty water tank regularly; clean with mild detergent monthly.
  3. Exterior Cleaning: Wipe cabinet with damp cloth; never use harsh chemicals.
  4. Coil Inspection: Check evaporator coils annually for dust buildup.
  5. Off-Season Storage: Empty tank, clean unit, and store in dry place.

WARNING! Always unplug unit before cleaning. Do not immerse in water.

Drainage Options

Two drainage methods: Manual (tank) and Continuous (hose).

Manual Drainage: Unit stops when tank is full; red LED illuminates. Empty tank and replace to resume operation.

Continuous Drainage: Connect 5/8" ID hose to drain port. Ensure hose runs downward without kinks. Unit will drain continuously without tank filling.

Energy Efficiency Tips

Close windows and doors during operation. Use timer to run during peak humidity hours. Clean filter regularly for optimal airflow. Set humidity to 45-50% for comfort and efficiency. Place unit in center of problem area for best results.

CAUTION! Do not operate below 41°F; frost may form on coils.

Regulatory Information

UL Listed: Meets UL 474 safety standards. Energy Star: Certified for energy efficiency. FCC Part 15: Class B digital device compliant. EPA Refrigerant: R410A, environmentally friendly. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/tank fullCheck power connection; empty water tank; reset circuit breaker.
Poor dehumidificationDirty filter/extreme tempsClean air filter; ensure room temp between 41°F-95°F.
Water leakageImproper hose connectionCheck hose for kinks; ensure proper connection to drain port.
Loud operationUneven surface/fan issuePlace on level surface; check for obstructions in fan area.
Display not workingPower interruptionUnplug for 10 minutes, then restart; check power source.
Frost on coilsLow temperatureMove to warmer area; defrost function should activate automatically.

Reset: Unplug for 10 minutes to reset electronic controls.

Service: 1-800-263-2629; www.danby.com