Danby Premiere DDR65CHP Dehumidifier Manual

The Danby Premiere DDR65CHP is a high-capacity 65-pint dehumidifier designed for residential use in spaces up to 4500 sq. ft. It features electronic controls, a digital display, 24-hour timer, continuous drain option, auto-defrost, washable filter, and adjustable humidity settings. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drain Hose 7. Operation Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic control panel, Digital display, Water tank with full indicator, Continuous drain port, Washable air filter, Casters for mobility.

FeatureDescription
Capacity65 pints per day (at 80°F, 60% RH)
Coverage AreaUp to 4500 sq. ft.
Digital DisplayShows humidity level, settings, and alerts
Electronic ControlsTouch buttons for mode, timer, fan speed
Auto DefrostPrevents coil freezing in low temperatures
Continuous DrainOption for hose connection (hose not included)
24-Hour TimerProgram on/off cycles
Washable FilterRemovable and reusable air filter
Full Tank AlertLight and audible signal when tank is full
CastersFour wheels for easy mobility

Installation

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place unit at least 12 inches from walls and furniture for proper airflow.
  2. Check filter: Ensure washable filter is properly installed.
  3. Power connection: Plug into a dedicated 115V AC, 60Hz outlet. Do not use extension cord.
  4. Drain option: For continuous drainage, attach hose to drain port (see Section 7).

WARNING! Ensure unit is upright for at least 24 hours before first use if transported on its side. Keep away from heat sources and water splashes.

First-Time Setup

Plug in unit; control panel will illuminate.

  1. Set humidity level: Press HUMIDITY button to select desired RH (30%-80%).
  2. Select mode: Choose between CONTINUOUS (runs until tank full/turned off) or AUTO (maintains set humidity).
  3. Set fan speed: Choose HIGH for maximum dehumidification or LOW for quiet operation.
  4. Program timer (optional): Use TIMER button to set automatic start/stop times.

CAUTION! Do not operate in temperatures below 41°F (5°C). Ensure water tank is properly seated before operation.

Specifications

Controls and Settings

Control Panel: POWER, MODE, HUMIDITY, FAN SPEED, TIMER, FILTER RESET.

Display Icons: Power, Mode (Continuous/Auto), Fan Speed (High/Low), Timer, Filter Alert, Full Tank, Defrost.

Humidity Setting: Adjust in 5% increments from 30% to 80% RH. Timer: Program up to 24 hours for automatic start/stop. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Filter Reset: Press after cleaning filter to reset alert. Auto Restart: Unit resumes previous settings after power interruption.

Connecting Drain Hose

For continuous drainage (recommended for basements, crawl spaces).

  1. Turn off and unplug unit.
  2. Remove drain cap from back of unit.
  3. Attach standard 5/8" ID garden hose (not included) to drain port.
  4. Route hose to floor drain or suitable drainage area (downward slope required).
  5. Ensure hose is not kinked or obstructed.

Tip: When using continuous drain, remove water tank. Unit will not stop when hose is connected.

Operation Modes

Two main operating modes:

  1. Continuous Mode: Runs continuously until tank is full or unit is turned off. Ideal for quickly reducing humidity.
  2. Auto Mode: Maintains set humidity level. Compressor cycles on/off automatically. Most energy-efficient for maintained spaces.
  3. Timer Function: Set start delay (1-24 hours) or shut-off delay. Useful for scheduling operation.
  4. Auto Defrost: Automatically activates when coil temperature drops below 41°F. Compressor pauses, fan continues.

WARNING! Do not operate in standing water. Ensure unit is on level surface to prevent tipping.

Maintenance

Regular maintenance ensures optimal performance and longevity.

Care & Cleaning

Unplug before any cleaning. Use mild detergent and soft cloth for exterior. Never use abrasive cleaners or solvents.

CAUTION! Do not immerse unit in water. Do not use water above 104°F (40°C) for cleaning. Ensure all parts are completely dry before reassembly.

Regulatory Information

UL Listed. Meets U.S. safety standards. This product contains refrigerant R410A. Do not vent refrigerant to atmosphere. For proper disposal, consult local regulations. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingNo power/tank fullCheck outlet; ensure plug is secure; empty water tank.
Reduced moisture removalDirty filter/extreme conditionsClean air filter; ensure room temp is between 41°F-95°F.
Water leakageTank not seated/hose connectionEnsure tank is properly inserted; check hose for leaks/kinks.
Loud noiseUneven surface/foreign objectPlace on level surface; check for objects near fan.
Display shows "FL"Filter needs cleaningClean filter, press FILTER RESET button.
Ice on coilsLow temperatureAuto-defrost should activate; move to warmer area if persistent.

Reset: Unplug for 5 minutes, then restart.

Service: 1-800-263-2629; www.danby.com