The Danby Premiere DDR65CHP is a high-capacity 65-pint dehumidifier designed for residential use in spaces up to 4500 sq. ft. It features electronic controls, a digital display, 24-hour timer, continuous drain option, auto-defrost, washable filter, and adjustable humidity settings. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Electronic control panel, Digital display, Water tank with full indicator, Continuous drain port, Washable air filter, Casters for mobility.
| Feature | Description |
|---|---|
| Capacity | 65 pints per day (at 80°F, 60% RH) |
| Coverage Area | Up to 4500 sq. ft. |
| Digital Display | Shows humidity level, settings, and alerts |
| Electronic Controls | Touch buttons for mode, timer, fan speed |
| Auto Defrost | Prevents coil freezing in low temperatures |
| Continuous Drain | Option for hose connection (hose not included) |
| 24-Hour Timer | Program on/off cycles |
| Washable Filter | Removable and reusable air filter |
| Full Tank Alert | Light and audible signal when tank is full |
| Casters | Four wheels for easy mobility |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Ensure unit is upright for at least 24 hours before first use if transported on its side. Keep away from heat sources and water splashes.
Plug in unit; control panel will illuminate.
CAUTION! Do not operate in temperatures below 41°F (5°C). Ensure water tank is properly seated before operation.
Control Panel: POWER, MODE, HUMIDITY, FAN SPEED, TIMER, FILTER RESET.
Display Icons: Power, Mode (Continuous/Auto), Fan Speed (High/Low), Timer, Filter Alert, Full Tank, Defrost.
Humidity Setting: Adjust in 5% increments from 30% to 80% RH. Timer: Program up to 24 hours for automatic start/stop. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Filter Reset: Press after cleaning filter to reset alert. Auto Restart: Unit resumes previous settings after power interruption.
For continuous drainage (recommended for basements, crawl spaces).
Tip: When using continuous drain, remove water tank. Unit will not stop when hose is connected.
Two main operating modes:
WARNING! Do not operate in standing water. Ensure unit is on level surface to prevent tipping.
Regular maintenance ensures optimal performance and longevity.
Unplug before any cleaning. Use mild detergent and soft cloth for exterior. Never use abrasive cleaners or solvents.
CAUTION! Do not immerse unit in water. Do not use water above 104°F (40°C) for cleaning. Ensure all parts are completely dry before reassembly.
UL Listed. Meets U.S. safety standards. This product contains refrigerant R410A. Do not vent refrigerant to atmosphere. For proper disposal, consult local regulations. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | No power/tank full | Check outlet; ensure plug is secure; empty water tank. |
| Reduced moisture removal | Dirty filter/extreme conditions | Clean air filter; ensure room temp is between 41°F-95°F. |
| Water leakage | Tank not seated/hose connection | Ensure tank is properly inserted; check hose for leaks/kinks. |
| Loud noise | Uneven surface/foreign object | Place on level surface; check for objects near fan. |
| Display shows "FL" | Filter needs cleaning | Clean filter, press FILTER RESET button. |
| Ice on coils | Low temperature | Auto-defrost should activate; move to warmer area if persistent. |
Reset: Unplug for 5 minutes, then restart.