The Danby Premiere DDR70B3PWP is a high-capacity 70-pint dehumidifier designed for residential use. It features electronic controls, a digital display, adjustable humidity settings, continuous drainage option, auto-restart, washable filter, and a built-in pump for vertical lift drainage. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drainage 7. Operating Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic control panel, Digital display, Water tank with full indicator, Continuous drain port, Built-in condensate pump, Washable air filter, Casters for mobility.

FeatureDescription
Capacity70 pints per day (at 60°F, 60% RH)
Control PanelElectronic touch controls with LED display
Humidity ControlAdjustable from 35% to 80% relative humidity
Water TankRemovable 1.5-gallon bucket with full alert and auto-shutoff
Continuous DrainGarden hose connection for gravity drainage
Built-in PumpCondensate pump for vertical lift up to 15 feet
Air FilterWashable mesh filter for improved air quality
Auto RestartResumes previous settings after power interruption
Timer24-hour on/off programmable timer
MobilityFour swivel casters for easy movement

Installation

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place unit at least 6 inches from walls and furniture for proper airflow.
  2. Power Connection: Plug into a dedicated 115V/60Hz grounded outlet.
  3. Initial Check: Ensure water tank is properly inserted and filter is clean.
  4. Drainage Setup: Attach hose to continuous drain port if using gravity drain, or connect pump hose for vertical drainage.

WARNING! Do not use extension cords. Ensure unit is upright before operating.

First-Time Setup

Power on dehumidifier; follow control panel prompts.

  1. Set Desired Humidity: Press HUMIDITY button to select target level (35%-80%).
  2. Select Mode: Choose between CONTINUOUS, AUTO, or DRY laundry mode.
  3. Timer Setup: Use TIMER button to program automatic start/stop times.
  4. Pump Setup: If using pump, ensure hose is connected and directed to drain location.

CAUTION! Allow unit to sit upright for 24 hours if transported horizontally.

Specifications

Controls and Settings

Access all functions via electronic control panel. Display shows current humidity, set point, timer, and alerts.

Control Buttons: POWER, HUMIDITY (up/down), MODE (Continuous/Auto/Laundry), TIMER (set hours), PUMP (on/off), FILTER (reset indicator).

Humidity Settings: Adjustable in 5% increments from 35% to 80%. Modes: CONTINUOUS (runs constantly), AUTO (cycles based on set point), LAUNDRY (high fan for drying clothes). Timer: Program up to 24 hours for automatic operation. Pump: Activate for vertical drainage. Filter Reset: Press after cleaning filter.

Connecting Drainage

Two drainage options: gravity continuous drain or pump-assisted vertical drain.

  1. Gravity Drain: Attach standard garden hose (¾") to drain port at back. Ensure hose runs downward to floor drain.
  2. Pump Drain: Connect included hose to pump outlet. Route hose upward (max 15 ft) to sink, drain, or outside.
  3. Select Drain Mode: On control panel, press PUMP button to activate pump drainage.

Tip: For pump use, ensure hose is not kinked and outlet is clear.

Operating Modes

Supports multiple operating modes for different needs.

  1. Auto Mode: Unit runs until set humidity is reached, then cycles on/off to maintain.
  2. Continuous Mode: Runs continuously regardless of humidity level.
  3. Laundry Mode: High fan speed to dry clothes in enclosed space.
  4. Timer Operation: Set unit to turn on/off at specific times within 24-hour period.
  5. Pump Operation: Enable when vertical drainage is required.

WARNING! Do not operate below 41°F; coil may freeze. Use in enclosed spaces only.

Maintenance

Regular maintenance ensures optimal performance and longevity.

Care & Cleaning

Unplug before cleaning. Use mild detergent and soft cloth only; do not immerse in water.

CAUTION! Never use gasoline, solvents, or abrasive cleaners. Keep water away from electrical components.

Regulatory Information

This dehumidifier complies with FCC Part 15 Class B limits for residential use. UL listed. Energy Star certified. Copyright © Danby Products Inc. For support, visit www.danby.com or contact 1-800-263-2629.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/full tankCheck outlet; ensure tank is empty and properly inserted.
Reduced moisture removalDirty filter/low temperatureClean filter; ensure room temp above 41°F.
Pump not workingHose blockage/air lockCheck hose for kinks; prime pump by briefly tilting unit.
Continuous runningHigh humidity/set point lowAdjust humidity set point higher; allow time to reach level.
Error codes on displaySensor/component faultUnplug for 5 minutes, restart. If persists, contact service.

Reset: Unplug for 5 minutes to reset electronic controls.

Service: 1-800-263-2629; www.danby.com